Suggested Loop Sensor Locations, Free Exit On Vehicle Approach, Entry With Access Control Device
View all LiftMaster MEGA SLIDE-X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
SUGGESTED LOOP SENSOR LOCATIONS FREE EXIT ON VEHICLE APPROACH Gate will open when sensed by open loop and then close once all loops are cleared if the close timer is on. Close input can be used to close gate before timer expires (Figure 1). Terminal #1, 2, and 3 are open inputs. Safety Loop Open Loop Terminal #5 is safety input. ENTRY WITH ACCESS CONTROL DEVICE Gate will open when activated by an access control device. When timer expires (if used), gate will close (Figure 2). Terminal #5 is safety input. Terminals #1, 2, and 3 are open inputs. Mega Slide X DUAL DIRECTION AS ENTRY AND FREE EXIT Dual direction is a combination of both of the above configurations to provide the ability for traffic to enter or exit in the same lane (Figure 3). Card Reader Tele-entry Radio Control RECOMMENDATION 1: If vehicle detectors are used to open or close the gate, use of the presence contacts are recommended. Using the pulse contacts will REDUCE the gate's safe operation. RECOMMENDATION 2: Use safety pressure sensing edges to prevent entrapment. RECOMMENDATION 3: Install ALL access control devices within view of gate. Card Reader Tele-entry Radio Control Safety Loop Safety Loop Mega Slide X Safety Loop Open Loop Mega Slide X 18