RECOMMENDED SITE LAYOUT EXAMPLE Please use all safety devices that may apply to your installation to achieve the safest operation. (This is a view from above gate.) Safety Photo Beam (NOTE-2) Stop Edge (NOTE-2 and 4) Edge Sensor (NOTE-2,3) Reversing Photo Beam (NOTE-2,3,4) Stop Edge (NOTE-2) Roadway Safety Zone Gate Operator Stop Photo Beam (NOTE-1) Stop Edge (NOTE-2 and 4) Gate Stops Here Stop Photo Beam (NOTE-1) Backframe Safety Zone Reversing Photo Beam (NOTE-2,and 4) Stop Edge (NOTE-2 and 4) Stationary/Fixed/Dead Panel Stop Edge (NOTE-2 and 4) Gate Stops Here Edge Sensor (NOTE-2,3,4) Stop Edge (NOTE-2 and 4) Reversing Photo Beam (NOTE-2,3) Stop Photo Beam (NOTE-1) Gate Operator NOTE-1: (Required) Secondary entrapment device (UL-325) NOTE-2: May be added as a third level of safety but is not to replace beams marked NOTE-1 NOTE-3: Reversing edge or beam will re-open a closing gate (use J5 #5) NOTE-4: Stop edge will stop gate while contacted (use JP2 connection) = Contact Edges This drawing is not to scale. NOTE: This unit to employ: Primary entrapment is an "A1" inherent entrapment sensing system with an audio alarm (reverses gate direction). Secondary entrapment is a "B1" a non-contact, photoelectric beam, connect at JP2 (stops gate, see NOTE-1). Use only UL recognized sensors. At least one secondary "stop" photo beam should be installed along the gate's path that is covered when open. Photo beams are to be installed according to their manufacturer's instructions and are to be placed in areas that pose a risk of entrapment. A separate pedestrian door is required per UL-325. It is recommended that all gates and operators be installed to conform to that latest ASTM F2200-02 requirements. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

6
RECOMMENDED SITE LAYOUT EXAMPLE
Please use all safety devices that may apply to your installation to
achieve the safest operation. (This is a view from above gate.)
NOTE-1:
(Required) Secondary entrapment device (UL-325)
NOTE-2:
May be added as a third level of safety but is not to
replace beams marked NOTE-1
NOTE-3:
Reversing edge or beam will re-open a closing gate
(use J5 #5)
NOTE-4:
Stop edge will stop gate while contacted
(use JP2 connection)
NOTE:
This unit to employ:
Primary entrapment is an “A1” inherent entrapment sensing
system with an audio alarm (reverses gate direction). Secondary
entrapment is a “B1” a non-contact, photoelectric beam, connect
at JP2 (stops gate, see NOTE-1). Use only UL recognized
sensors. At least one secondary “stop” photo beam should be
installed along the gate’s path that is covered when open. Photo
beams are to be installed according to their manufacturer’s
instructions and are to be placed in areas that pose a risk of
entrapment. A separate pedestrian door is required per UL-325.
It is recommended that all gates and operators be installed to
conform to that latest ASTM F2200-02 requirements.
Gate Stops Here
Gate Stops Here
Edge Sensor (NOTE-2,3)
Edge Sensor (NOTE-2,3,4)
Reversing Photo Beam (NOTE-2,3,4)
Reversing Photo Beam (NOTE-2,3)
Reversing Photo Beam (NOTE-2,and 4)
Roadway Safety Zone
Stationary/Fixed/Dead Panel
= Contact Edges
Backframe Safety Zone
Stop Photo Beam (NOTE-1)
Stop Photo Beam (NOTE-1)
Stop Edge (NOTE-2)
Gate Operator
Gate Operator
Stop Edge (NOTE-2 and 4)
Stop Edge (NOTE-2 and 4)
Stop Edge (NOTE-2 and 4)
Stop Edge (NOTE-2 and 4)
Stop Edge (NOTE-2 and 4)
Safety Photo Beam (NOTE-2)
Stop Photo Beam (NOTE-1)
This drawing is not to scale.