Maytag MDB4651AWS Installation Instructions - Page 11
Using UL-listed/CSA
View all Maytag MDB4651AWS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
5, Using UL-listed/CSA approved twist-on connectors sized to connect power supply cord to 16-gauge dishwasher wire, connect the black wire from the power supply cord to the black wire on the terminal box. 6, Tighten the conduit connector screws to secure the power supply cord. 1, Measure the cabinet opening height. 7. Insert tabs on the left-hand side of the terminal box cover. 8. Using a V4"nut driver and previously removed screw, reinstall the terminal box cover with the wires inside terminal box. 2, Adjust the dishwasher leg height according to the following chart. Turn both of the leveler legs to the same height. Height (H) Adjusted Leg Height Height (X) (H) Adjusted Leg Height (X) 33W' (85.1 cm) 0" 338/8'' (85.4 cm) V8" (0.3 cm) 333/4'' (85.7 cm) V4" (0.6 cm) 337/8'' (86 cm) 3/8"(1 cm) 34" (86.4 cm) V2" (1.3 cm) 34V8" (86.7 cm) 8/8"(1.6 cm) 34V4" (87 cm) 3/4"(1.9 cm) 34%" (87.4 cm) 34W' (87.7 cm) 348/8'' (88 cm) 343/4'' (88.3 cm) 347/8'' (88.6 cm) 35" (88.9 cm) %" (2.2 cm) 1" (2.5 cm) 1V8" (2.8 cm) 1V4" (3.1 cm) 13/8"(3.5 cm) 1V2" (3.8 cm) \\ \ \ 9. Check that no wires are pinched by the cover. NOTE: Do not plug power supply cord into outlet until instructed. 11