Maytag MDB4651AWS Installation Instructions - Page 5
Installationinstructions - parts
View all Maytag MDB4651AWS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Requirements: • 120-volt, 60 Hz, AC-only, 15- or 20-amp fused electrical supply • Copper wire only, 2 wire with ground Recommended: • Time-delay fuse or circuit breaker • Separate circuit Direct Wire Connection • Use flexible, armored or nonmetalic sheathed, copper wire with grounding wire that meets the wiring requirements for your home and local codes and ordinances. • Use a UL-listed/CSA-approved conduit connector. Power Supply Cord Connection Use Power Supply Cord Kit (Part Number 4317824) marked for use with dishwashers. Kit contents include: • Voltex, Inc., UL-listed 16-gauge 3-wire power supply cord with a 3 prong grounding plug • Neer C-500 7/8"strain relief • 3 wire connectors • Grommet (Part Number 302797) Follow the kit instructions for installing the power supply cord. NOTE: Power supply cord must plug into a mating, grounded 3 prong outlet, located in the cabinet next to the dishwasher opening. Outlet must meet all local codes and ordinances. IMPORTANT: If you plan to install a garbage disposal, an additional separate 120-volt, 60 Hz, AC-only, 15- or 20-amp fused electrical supply is required. Use the new drain hose supplied with your dishwasher. NOTI:: If a longer drain hose is required: • Use a new drain hose with maximum length of 12 ft (3.7 m) that meets all current AHAM/IAPMO test standards. • Use a new drain hose that is resistant to heat and detergent. • Use a new drain hose that fits the 1" (2.5 cm) drain connector on the dishwasher. • Connect drain hose to waste tee or disposal inlet above drain trap in house plumbing. • Connect drain hose to house plumbing 20" (50.8 cm) minimum above the floor. NOTE: It is recommended that the drain hose either be looped up and securely fastened to the underside of the counter, or be connected to an air gap. • Use a drain air gap if the drain hose is connected to house plumbing lower than 20" (50.8 cm) above the subfloor or floor. Drain Air Gap • A hot water line with 20-120 psi (138-862 kPa) water pressure. • 120°F (49°C) water temperature at dishwasher. • 3/8"O.D. copper tubing with compression fitting or flexible braided water supply line. NOTE: Y2" minimum plastic tubing is not recommended. • 90 ° elbow with %" N.RT. external pipe threads on one end. IMPORTANT: Do not solder within 6" (15.2 cm) from water inlet valve. • Use V2" (1.3 cm) minimum I.D. drain line fittings. • If required, the drain air gap should be installed in accordance with the drain air gap installation instructions. When connecting the drain air gap, a rubber hose (not provided) will be needed to connect to the waste tee or disposer inlet. NOTE: Do not connect drain lines from other devices to the dishwasher drain hose. INSTALLATIONINSTRUCTIONS 1. Check that the water supply line reaches to the front left-hand side of the opening where the water connection will be made. 2. Check that the direct wire reaches to the front right-hand side of the opening where the electrical connection will be made. ))! A Electrical Shock Hazard Disconnect electrical power at the fuse box or circuit breaker box before installing dishwasher. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Turn off water supply. Follow the steps in this section if you are installing the dishwasher in an existing cabinet opening with utility hookups. 6 It (15.2 cm) B A. Water supply fine B. Direct wire 3. If the existing utilities extend to the locations shown, see "Install Drain Hose." 4. If the utilities do not extend to the locations shown, see "Prepare Cabinet Opening--No Existing Utility Hookups."