Requirements: • 120-volt, 60 Hz, AC-only, 15- or 20-amp fused electrical supply • Copper wire only, 2 wire with ground Recommended: • Time-delay fuse or circuit breaker • Separate circuit Direct Wire Connection • Use flexible, armored or nonmetalic sheathed, copper wire with grounding wire that meets the wiring requirements for your home and local codes and ordinances. • Use a UL-listed/CSA-approved conduit connector. Power Supply Cord Connection Use Power Supply Cord Kit (Part Number 4317824) marked for use with dishwashers. Kit contents include: • Voltex, Inc., UL-listed 16-gauge 3-wire power supply cord with a 3 prong grounding plug • Neer C-500 7/8"strain relief • 3 wire connectors • Grommet (Part Number 302797) Follow the kit instructions for installing the power supply cord. NOTE: Power supply cord must plug into a mating, grounded 3 prong outlet, located in the cabinet next to the dishwasher opening. Outlet must meet all local codes and ordinances. IMPORTANT: If you plan to install a garbage disposal, an additional separate 120-volt, 60 Hz, AC-only, 15- or 20-amp fused electrical supply is required. Use the new drain hose supplied with your dishwasher. NOTI:: If a longer drain hose is required: • Use a new drain hose with maximum length of 12 ft (3.7 m) that meets all current AHAM/IAPMO test standards. • Use a new drain hose that is resistant to heat and detergent. • Use a new drain hose that fits the 1" (2.5 cm) drain connector on the dishwasher. • Connect drain hose to waste tee or disposal inlet above drain trap in house plumbing. • Connect drain hose to house plumbing 20" (50.8 cm) minimum above the floor. NOTE: It is recommended that the drain hose either be looped up and securely fastened to the underside of the counter, or be connected to an air gap. • Use a drain air gap if the drain hose is connected to house plumbing lower than 20" (50.8 cm) above the subfloor or floor. Drain Air Gap • A hot water line with 20-120 psi (138-862 kPa) water pressure. • 120°F (49°C) water temperature at dishwasher. • 3/8"O.D. copper tubing with compression fitting or flexible braided water supply line. NOTE: Y2" minimum plastic tubing is not recommended. • 90 ° elbow with %" N.RT. external pipe threads on one end. IMPORTANT: Do not solder within 6" (15.2 cm) from water inlet valve. • Use V2" (1.3 cm) minimum I.D. drain line fittings. • If required, the drain air gap should be installed in accordance with the drain air gap installation instructions. When connecting the drain air gap, a rubber hose (not provided) will be needed to connect to the waste tee or disposer inlet. NOTE: Do not connect drain lines from other devices to the dishwasher drain hose. INSTALLATIONINSTRUCTIONS 1. Check that the water supply line reaches to the front left-hand side of the opening where the water connection will be made. 2. Check that the direct wire reaches to the front right-hand side of the opening where the electrical connection will be made. ))! A Electrical Shock Hazard Disconnect electrical power at the fuse box or circuit breaker box before installing dishwasher. Failure to do so can result in death or electrical shock. 1. Disconnect power. 2. Turn off water supply. Follow the steps in this section if you are installing the dishwasher in an existing cabinet opening with utility hookups. 6 It (15.2 cm) B A. Water supply fine B. Direct wire 3. If the existing utilities extend to the locations shown, see "Install Drain Hose." 4. If the utilities do not extend to the locations shown, see "Prepare Cabinet Opening--No Existing Utility Hookups."

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Requirements:
120-volt,
60 Hz, AC-only,
15- or 20-amp
fused electrical
supply
Copper wire only, 2 wire with ground
Recommended:
Time-delay
fuse or circuit
breaker
Separate
circuit
Direct
Wire Connection
Use flexible,
armored
or nonmetalic
sheathed,
copper
wire
with grounding
wire that meets the wiring requirements
for
your home and local codes and ordinances.
Use a UL-listed/CSA-approved
conduit
connector.
Power
Supply
Cord Connection
Use Power Supply Cord Kit (Part Number
4317824) marked for
use with
dishwashers.
Kit contents
include:
Voltex, Inc., UL-listed
16-gauge 3-wire
power supply
cord with
a 3 prong grounding
plug
Neer C-500 7/8"strain relief
3 wire connectors
Grommet
(Part Number 302797)
Follow the kit instructions
for installing
the power supply
cord.
NOTE: Power supply
cord must plug into a mating, grounded
3 prong outlet,
located in the cabinet next to the dishwasher
opening.
Outlet must meet all local codes and ordinances.
IMPORTANT:
If you plan to install a garbage disposal,
an
additional
separate
120-volt, 60 Hz, AC-only, 15- or 20-amp
fused
electrical
supply
is required.
A hot water line with 20-120
psi (138-862
kPa) water pressure.
120°F (49°C) water temperature
at dishwasher.
3/8"O.D. copper tubing
with compression
fitting or flexible
braided
water supply
line.
NOTE:
Y2"
minimum
plastic tubing
is not recommended.
90 ° elbow with %" N.RT. external
pipe threads
on one end.
IMPORTANT:
Do not solder within 6" (15.2 cm) from water inlet
valve.
Use the new drain hose supplied
with your dishwasher.
NOTI::
If a longer drain hose is required:
Use a new drain hose with maximum
length of 12 ft (3.7 m)
that meets all current AHAM/IAPMO
test standards.
Use a new drain hose that is resistant to heat and
detergent.
Use a new drain hose that fits the 1" (2.5 cm) drain
connector
on the dishwasher.
Connect
drain hose to waste
tee or disposal
inlet above drain
trap in house plumbing.
Connect
drain hose to house plumbing
20" (50.8 cm)
minimum
above the floor.
NOTE: It is recommended
that the drain hose either be looped
up
and securely
fastened
to the underside
of the counter,
or be
connected
to an air gap.
Use a drain air gap if the drain hose is connected
to house
plumbing
lower than 20" (50.8 cm) above the subfloor
or floor.
Drain Air Gap
Use
V2"
(1.3 cm) minimum
I.D. drain line fittings.
If required, the drain air gap should be installed in accordance
with the drain air gap installation
instructions.
When
connecting
the drain air gap, a rubber
hose (not provided) will
be needed
to connect
to the waste tee or disposer
inlet.
NOTE: Do not connect
drain lines from other devices
to the
dishwasher
drain hose.
INSTALLATIONINSTRUCTIONS
Electrical
Shock
Hazard
Disconnect
electrical
power at the
fuse
box or circuit
breaker
box before
installing
dishwasher.
Failure to do so can result in death or electrical
shock.
1.
Disconnect
power.
2.
Turn off water supply.
Follow the steps in this section
if you are installing the dishwasher
in an existing cabinet
opening
with utility hookups.
1.
Check that the water supply
line reaches to the front
left-hand
side of the opening where the water connection
will be made.
2.
Check that the direct wire reaches to the front right-hand
side
of the opening
where the electrical connection
will be made.
))!
A
6
It
(15.2
cm)
B
A. Water supply
fine
B. Direct
wire
3.
4.
If the existing
utilities extend
to the locations
shown, see
"Install
Drain Hose."
If the utilities
do not extend to the locations
shown, see
"Prepare Cabinet
Opening--No
Existing
Utility Hookups."