Prepare your 3-wire cable, for direct connection, Remove center screw, Connect neutral wire, Wire
View all Maytag MED7500YW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
3-Wire Direct Wire Connection Use where local codes permit connecting cabinet-ground conductor to neutral wire. 3. Connect neutral wire 1. Prepare your 3-wire cable B for direct connection D (251"mm) (893m½m" ) Direct wire cable must have 5 ft. (1.52 m) of extra length so dryer may be moved if needed. Strip 31/2" (89 mm) of outer covering from end of cable. Strip insulation back 1" (25 mm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape wire ends into hooks. 2. Remove center screw Place hooked end of neutral wire (white or center) (D) of direct wire cable under center terminal block screw (B), hook facing right. Squeeze hooked end together. Tighten screw. 4. Connect remaining wires Remove center terminal block screw (B). Place hooked ends of remaining direct wire cable wires under B outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Replace the terminal block cover on the back of the dryer. Tighten strain relief nut. Now, go to" Venting Requirements." 17