Miele Crystal G 5285 SCVi Operating and Installation manual - Page 59

Hardwired electrical connection, GROUNDING INSTRUCTIONS, THIS APPLIANCE MUST BE, GROUNDED., V, 60 Hz

Page 59 highlights

Electrical connection Hardwired electrical connection It is possible to hardwire this appliance to an existing power cable. ,CAUTION: Before servicing, disconnect the power supply by either removing the fuse, shutting off the power main or manually "tripping" the circuit breaker. Installation work and repairs should only be performed by a qualified technician in accordance with all applicable codes and standards. Repairs and service by unqualified persons could be dangerous and the manufacturer cannot be held responsible. Before connecting the appliance to the power supply, make sure that the voltage and frequency listed on the data plate correspond with the household electrical supply. This data must correspond to prevent machine damage. Consult an electrician if in doubt. ,Prior to making a hardwire connection to the terminal, remove the power cord. Otherwise there will be a risk of electric shock from the attached plug. An existing flexible supply cord or cable shall have a minimum thickness of AWG 14. 120 V, 60 Hz, 15 A fuse rating Black wire (live): connect to L White wire (neutral): connect to N Green wire (ground): connect to - ,After attaching the permanent power supply cord, check that all screws on the terminal block and the strain relief are tightened. GROUNDING INSTRUCTIONS THIS APPLIANCE MUST BE GROUNDED. This appliance must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance. 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

Hardwired electrical connection
It is possible to hardwire this appliance
to an existing power cable.
,
CAUTION: Before servicing,
disconnect the power supply by
either removing the fuse, shutting off
the power main or manually
"tripping" the circuit breaker.
Installation work and repairs should
only be performed by a qualified
technician in accordance with all
applicable codes and standards.
Repairs and service by unqualified
persons could be dangerous and
the manufacturer cannot be held
responsible.
Before connecting the appliance to
the power supply, make sure that
the voltage and frequency listed on
the data plate correspond with the
household electrical supply. This
data must correspond to prevent
machine damage. Consult an
electrician if in doubt.
GROUNDING INSTRUCTIONS
THIS APPLIANCE MUST BE
GROUNDED.
This appliance must be connected to a
grounded metal, permanent wiring
system, or an equipment-grounding
conductor must be run with the circuit
conductors and connected to the
equipment-grounding terminal or lead
on the appliance.
,
Prior to making a hardwire
connection to the terminal, remove
the power cord. Otherwise there will
be a risk of electric shock from the
attached plug.
An existing flexible supply cord or
cable shall have a minimum thickness
of AWG 14.
120 V, 60 Hz, 15 A fuse rating
Black wire (live):
connect to L
White wire (neutral):
connect to N
Green wire (ground):
connect to
-
,
After attaching the permanent
power supply cord, check that all
screws on the terminal block and the
strain relief are tightened.
Electrical connection
59