NEC VT695 NP115 : RS232 codes- Projectors - Page 13

NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the term DVI

Page 13 highlights

NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the term "DVI connector" has been changed to "COMPUTER". 006. RUNNING SENSE Function: This command acquires the operation mode of the projector. Command: 00H 81H 00H 00H 00H 81H Response: At the time of a success 20H 81H 01H xxH 01H DATA01 CKS (*1) (*2) (*3) Data Portion Contents DATA01 Status of operation Bit 7: Power On/Off processing 0 = No execution (Normal condition) 1 = During execution Bit 6: Selecting signal processing 0 = No execution (Normal condition) 1 = During execution Bit 5: Cooling processing 0 = No execution (Normal condition) 1 = During execution Bit 4: External control mode 0 = OFF 1 = ON Bit 3: No Power-Off period 0 = Power-Off Possible (Normal condition) 1 = Power-Off Impossible Bit 2: Reserved Bit 1: Projector status 0 = Idling 1 = Power On Bit 0: Reserved Response: At the time of a failure A0H 81H 01H xxH 02H DATA1H DATA02 CKS (*1) (*2) (*4) (*3) 007. COMMON DATA REQUEST Function: This command acquires all of the detailed conditions of the projector. Command: 00H C0H 00H 00H 00H C0H Response: At the time of a success

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

NP310/NP410/MP410W/NP510/NP510W/NP610WS/NP610/NP610S and VT595/VT695/VT700, the term "DVI
connector" has been changed to "COMPUTER".
006. RUNNING SENSE
**********************************************************************
Function:
This command acquires the operation mode of the projector.
Command:
00H
81H
00H
00H
00H
81H
Response: At the time of a success
20H
81H
01H
xxH
01H
DATA01
CKS
(*1)
(*2)
(*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01
Status of operation
Bit 7: Power On/Off processing
0 = No execution (Normal condition)
1 = During execution
Bit 6: Selecting signal processing
0 = No execution (Normal condition)
1 = During execution
Bit 5: Cooling processing
0 = No execution (Normal condition)
1 = During execution
Bit 4: External control mode
0 = OFF
1 = ON
Bit 3: No Power-Off period
0 = Power-Off Possible (Normal condition)
1 = Power-Off Impossible
Bit 2: Reserved
Bit 1: Projector status
0 = Idling
1 = Power On
Bit 0: Reserved
Response: At the time of a failure
A0H
81H
01H
xxH
02H
DATA1H
DATA02
CKS
(*1)
(*2)
(*4)
(*3)
007. COMMON DATA REQUEST
**********************************************************************
Function:
This command acquires all of the detailed conditions of the projector.
Command:
00H
C0H
00H
00H
00H
C0H
Response: At the time of a success