NEC VT695 NP115 : RS232 codes- Projectors - Page 28

DATA09 .. 12 : Lamp Use Warning Starting TimeNormal mode second

Page 28 highlights

DATA05 .. 08 : Reserved DATA09 .. 12 : Lamp Use Warning Starting Time(Normal mode) (second) DATA13 .. 16 : Lamp Use Prohibited Time(Normal mode) (second) Response: At the time of a failure A3H 8CH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) Supplement: Example for acquiring remaining lamp time (in terms of Normal mode values) : Lamp Hour Meter (Normal mode) DATA01 DATA02 DATA03 DATA04 30H 2AH 00H 00H : 10800 seconds Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA04 DATA03 DATA02 DATA01 (00002A30) 3) Change from HEX to Decimal - value will change to 10800 seconds : Starting time for lamp usage warning message (in terms of Normal mode values) DATA09 DATA10 DATA11 DATA12 00H DDH 6DH 00H : 7200000 second Calculator Procedure 1) Set calculator to HEX 2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00) 3) Change from HEX to Decimal - value will change to 7200000 seconds Lamp remaining time (in terms of Normal mode values) = (7200000 - 10800) / 3600 = 1997 hour 037-2. LAMP INFORMATION REQUEST 2 Function: This command acquires lamp remaining amount. Command: 03H 94H 00H 00H 00H 97H Response: At the time of a success 23H 94H 01H xxH 05H DATA01 .. DATA05 CKS (*1) (*2) (*3) Data Portion Contents DATA01 .. 04 Reserved DATA05 lamp remaining amount (100% to -10%) Response: At the time of a failure A3H 94H 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

DATA05 .. 08 : Reserved
DATA09 .. 12 : Lamp Use Warning Starting Time(Normal mode) (second)
DATA13 .. 16 : Lamp Use Prohibited Time(Normal mode) (second)
Response: At the time of a failure
A3H
8CH
01H
xxH
02H
DATA01
DATA02
CKS
(*1)
(*2)
(*4)
(*3)
Supplement:
Example for acquiring remaining lamp time (in terms of Normal mode values)
: Lamp Hour Meter (Normal mode)
DATA01
DATA02
DATA03
DATA04
30H
2AH
00H
00H
:
10800 seconds
Calculator Procedure
1) Set calculator to HEX
2) Punch in DATA04 DATA03 DATA02 DATA01 (00002A30)
3) Change from HEX to Decimal - value will change to 10800 seconds
: Starting time for lamp usage warning message (in terms of Normal mode values)
DATA09
DATA10
DATA11
DATA12
00H
DDH
6DH
00H :
7200000 second
Calculator Procedure
1) Set calculator to HEX
2) Punch in DATA12 DATA11 DATA10 DATA09 (006DDD00)
3) Change from HEX to Decimal - value will change to 7200000 seconds
Lamp remaining time (in terms of Normal mode values)
= (7200000 - 10800) / 3600 = 1997 hour
037-2. LAMP INFORMATION REQUEST 2
**********************************************************************
Function:
This command acquires lamp remaining amount.
Command:
03H
94H
00H
00H
00H
97H
Response: At the time of a success
23H
94H
01H
xxH
05H
DATA01 .. DATA05
CKS
(*1)
(*2)
(*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 .. 04
Reserved
DATA05
lamp remaining amount (100% to -10%)
Response: At the time of a failure
A3H
94H
01H
xxH
02H
DATA01
DATA02
CKS
(*1)
(*2)
(*4)
(*3)