Nikon 9282 User Manual - Page 155
Analog-to-digital A/D
![]() |
UPC - 018208092826
View all Nikon 9282 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 155 highlights
Analog-to-digital (A/D) conversion 14 bits per color (RGB) Output Full color (8 or 16 bits per color [RGB]) Focus Autofocus, Manual Scanning time Duration of Scanning on processes ICE ROC GEM Preview Scan - - - 15 s 38 s ✔ - - 15 s 1 m 20 s - ✔ - 52 s 1 m 00 s - - ✔ 52 s 2 m 40 s - ✔ ✔ 52 s 2 m 05 s ✔ ✔ - 56 s 1 m 35 s ✔ - ✔ 56 s 2 m 50 s ✔ ✔ ✔ 56 s 2 m 55 s Computer: RAM: OS: Software: Board: Adapter: Input Resolution: Scan Bit Depth: CMS: Film: FMV715GTX6 (Pentium 4 1.5GHz) 1GB Windows 2000 Nikon Scan 3.1 IEEE 1394 I/F Board (included in the 4000 ED package) MA-20 (S) Slide Mount Adapter 4000dpi 14bit On Positive Interface IEEE 1394 Power supply AC 100-240 V, 50/60 Hz Maximum power consumption while scanning Not exceeding 20W Power consumption at standby Not exceeding 10W Operating environment • Temperature: +10 - +35°C (+50 - +95°F) • Humidity: 20-60% Dimensions 93 × 169 × 315 mm/3.66˝ × 6.65˝ × 12.40˝ (W × H × D) Weight Approximately 3 kg/6 lb 11.1 oz (accessories not included) Installation Vertical*/Horizontal† * Vertical installation not possible with optional SF-200 (S) slide feeder † Horizontal installation not possible with optional SA-30 film roll adapter 145
![](/manual_guide/products/nikon-9282-user-manual-0ac0df7/155.png)