The correspondence readings between temperature measured by thermistor and HEX readings

Page 105 highlights

KX-MC6020HX 2. Safety Protection a. 2 thermostats are provided with the Fuser unit, and the heater circuit is shut down when their surface temperatures becomes over 180°C. b. When the temperature becomes over 205°C, The heater control circuit of IC300 has the built-in function that the software turns off the heater control automatically. (The detection temperature takes place every 10msec.) c. When the Fuser unit can not be controlled by the software and the temperature becomes over 210°C, the heater control circuit of IC600 should be stopped forcibly by the hardware (IC830). The correspondence readings between temperature measured by thermistor and HEX readings Temperature AD Value (DEC) HEX reading Temperature AD Value (DEC) HEX reading (°C) (°C) -20 255 FF 25 248 F8 -10 254 FE 26 247 F7 0 253 FD 27 247 F7 1 253 FD 28 247 F7 2 253 FD 29 246 F6 3 253 FD 30 246 F6 4 253 FD 31 246 F6 5 252 FC 32 245 F5 6 252 FC 33 245 F5 7 252 FC 34 244 F4 8 252 FC 35 244 F4 9 252 FC 36 244 F4 10 252 FC 37 243 F3 11 251 FB 38 243 F3 12 251 FB 39 242 F2 13 251 FB 40 242 F2 14 251 FB 41 241 F1 15 251 FB 42 241 F1 16 250 FA 43 240 F0 17 250 FA 44 239 EF 18 250 FA 45 239 EF 19 250 FA 46 238 EE 20 249 F9 47 238 EE 21 249 F9 48 237 ED 22 249 F9 49 236 EC 23 248 F8 50 236 EC 24 248 F8 51 235 EB 79 209 D1 137 122 7A 80 208 D0 138 120 78 81 206 CE 139 119 77 82 205 CD 140 117 75 83 204 CC 141 116 74 84 203 CB 142 114 72 85 201 C9 143 113 71 Temperature AD Value (DEC) HEX reading (°C) 52 234 EA 53 234 EA 54 233 E9 55 232 E8 56 231 E7 57 231 E7 58 230 E6 59 229 E5 60 228 E4 61 227 E3 62 226 E2 63 225 E1 64 225 E1 65 224 E0 66 223 DF 67 222 DE 68 221 DD 69 220 DC 70 219 DB 71 218 DA 72 217 D9 73 216 D8 74 214 D6 75 213 D5 76 212 D4 77 211 D3 78 210 D2 195 53 35 196 52 34 197 51 33 198 50 32 199 50 32 200 49 31 201 48 30 105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336
  • 337
  • 338
  • 339
  • 340
  • 341
  • 342
  • 343
  • 344
  • 345
  • 346
  • 347
  • 348
  • 349
  • 350
  • 351
  • 352
  • 353
  • 354
  • 355
  • 356
  • 357
  • 358
  • 359
  • 360
  • 361
  • 362
  • 363
  • 364
  • 365
  • 366
  • 367
  • 368
  • 369
  • 370
  • 371
  • 372
  • 373
  • 374
  • 375
  • 376
  • 377
  • 378
  • 379
  • 380
  • 381
  • 382
  • 383
  • 384
  • 385
  • 386
  • 387
  • 388
  • 389
  • 390
  • 391
  • 392
  • 393
  • 394
  • 395
  • 396
  • 397
  • 398
  • 399
  • 400
  • 401
  • 402
  • 403
  • 404
  • 405
  • 406
  • 407
  • 408
  • 409
  • 410
  • 411
  • 412
  • 413
  • 414
  • 415
  • 416
  • 417
  • 418
  • 419
  • 420
  • 421
  • 422
  • 423
  • 424
  • 425
  • 426
  • 427
  • 428
  • 429
  • 430
  • 431
  • 432
  • 433
  • 434
  • 435
  • 436
  • 437
  • 438
  • 439
  • 440
  • 441
  • 442
  • 443
  • 444
  • 445
  • 446
  • 447
  • 448
  • 449
  • 450
  • 451
  • 452
  • 453
  • 454
  • 455
  • 456
  • 457
  • 458
  • 459
  • 460
  • 461
  • 462
  • 463
  • 464
  • 465
  • 466
  • 467
  • 468
  • 469
  • 470
  • 471
  • 472
  • 473
  • 474
  • 475
  • 476
  • 477
  • 478
  • 479
  • 480
  • 481
  • 482
  • 483
  • 484
  • 485
  • 486

105
KX-MC6020HX
2. Safety Protection
a. 2 thermostats are provided with the Fuser unit, and the heater circuit is shut down when their surface temperatures
becomes over 180
°
C.
b. When the temperature becomes over 205
°
C, The heater control circuit of IC300 has the built-in function that the software
turns off the heater control automatically. (The detection temperature takes place every 10msec.)
c. When the Fuser unit can not be controlled by the software and the temperature becomes over 210
°
C, the heater control
circuit of IC600 should be stopped forcibly by the hardware (IC830).
The correspondence readings between temperature measured by thermistor and HEX readings
Temperature
(
°
C
)
AD Value (DEC)
HEX reading
Temperature
(
°
C
)
AD Value (DEC)
HEX reading
Temperature
(
°
C
)
AD Value (DEC)
HEX reading
-20
255
FF
25
248
F8
52
234
EA
-10
254
FE
26
247
F7
53
234
EA
0
253
FD
27
247
F7
54
233
E9
1
253
FD
28
247
F7
55
232
E8
2
253
FD
29
246
F6
56
231
E7
3
253
FD
30
246
F6
57
231
E7
4
253
FD
31
246
F6
58
230
E6
5
252
FC
32
245
F5
59
229
E5
6
252
FC
33
245
F5
60
228
E4
7
252
FC
34
244
F4
61
227
E3
8
252
FC
35
244
F4
62
226
E2
9
252
FC
36
244
F4
63
225
E1
10
252
FC
37
243
F3
64
225
E1
11
251
FB
38
243
F3
65
224
E0
12
251
FB
39
242
F2
66
223
DF
13
251
FB
40
242
F2
67
222
DE
14
251
FB
41
241
F1
68
221
DD
15
251
FB
42
241
F1
69
220
DC
16
250
FA
43
240
F0
70
219
DB
17
250
FA
44
239
EF
71
218
DA
18
250
FA
45
239
EF
72
217
D9
19
250
FA
46
238
EE
73
216
D8
20
249
F9
47
238
EE
74
214
D6
21
249
F9
48
237
ED
75
213
D5
22
249
F9
49
236
EC
76
212
D4
23
248
F8
50
236
EC
77
211
D3
24
248
F8
51
235
EB
78
210
D2
79
209
D1
137
122
7A
195
53
35
80
208
D0
138
120
78
196
52
34
81
206
CE
139
119
77
197
51
33
82
205
CD
140
117
75
198
50
32
83
204
CC
141
116
74
199
50
32
84
203
CB
142
114
72
200
49
31
85
201
C9
143
113
71
201
48
30