Panasonic WV-CF294T Color Cctv Camera-english/french - Page 11

Installations And Connections, Preparations

Page 11 highlights

Installations and Connections Caution: ONLY CONNECT THIS TO 24 V AC OR 12 V DC CLASS 2 POWER SUPPLY. The following installation should be made by qualified service personnel or system installers. I Preparations Important: • Procure 4 mounting screws according to the material of the installation area. In this case, wood screws and nails should not be used. Recommended tightening torque is as follows. M4: 1.6 N·m {16 kgf·cm} • Required pull-out capacity of a single screw/bolt is 196 N {20 kgf} or more. • If a ceiling board such as plaster board is too weak to support the total weight, the area shall be sufficiently reinforced. • The protection sheet attached to the dome cover shall be peeled off after installation. 46 mm {1-13/16"} 4.5 mm Side cable access hole {3/16"} Camera fixing hole ø4 - 4.5 mm {3/16"} Cable access hole for wall/ceiling ø30 - 50 mm {1-3/16" - 2"} UTP cable access hole ø12 mm {1/2"} ø129.5 mm {5-1/8"} 83.5 mm {3-5/16"} G Direct mounting If the camera is directly mounted on a wall/ceiling, align the camera mounting position with the position of the hole through which the cables run and make the hole. If no hole is made through a wall/ceiling and open wiring along a wall/ceiling is used, process the cover so that the cables can be run through the side of the cover. G Using a two-gang junction box When using a two-gang junction box (4" x 4"), procure one locally that meets the dimensions in the figure. And then, locally procure four cameramounting screws suitable for the installation surface and structure of the wall/ceiling or two-gang junction box. Processed section of the side surface of the cover 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Direct mounting
If the camera is directly mounted on a
wall/ceiling, align the camera mounting posi-
tion with the position of the hole through
which the cables run and make the hole.
If no hole is made through a wall/ceiling and
open wiring along a wall/ceiling is used,
process the cover so that the cables can be
run through the side of the cover.
11
Installations and Connections
The following installation should be made by qualified service personnel or system installers.
Preparations
Important:
• Procure 4 mounting screws according to the material of the installation area. In this case,
wood screws and nails should not be used.
Recommended tightening torque is as follows.
M4: 1.6 N·m {16 k
g
f·cm}
Required pull-out capacity of a single screw/bolt is 196 N {20 k
g
f} or more.
• If a ceiling board such as plaster board is too weak to support the total weight, the area
shall be sufficiently reinforced.
The protection sheet attached to the dome cover shall be peeled off after installation.
UTP cable access hole
ø
12 mm {1/2"}
83.5 mm {3-5/16"}
ø
129.5 mm {5-1/8"}
4.5 mm
{3/16"}
46 mm {1-13/16"}
<Back/upper>
Cable access hole for wall/ceiling
ø
30 - 50 mm {1-3/16" - 2"}
Side cable access hole
Camera fixing hole
ø
4 - 4.5 mm {3/16"}
Using a two-gang junction box
When using a two-gang junction box (4" x
4"), procure one locally that meets the
dimensions in the figure.
And then, locally procure four camera-
mounting screws suitable for the installation
surface and structure of the wall/ceiling or
two-gang junction box.
Processed section of the side
surface of the cover
Caution:
ONLY CONNECT THIS TO 24 V AC OR 12 V DC CLASS 2 POWER SUPPLY.