Panasonic WVNP244 WVNP244 User Guide - Page 34

Con the settings relating to Panasonic alarm protocol [Panasonic alarm, protocol]

Page 34 highlights

Configure the settings relating to Panasonic alarm protocol [Panasonic alarm protocol] Click the [Notification] tab on the "Alarm setup" page. (☞ page 16) The settings relating to Panasonic alarm protocol can be configured on this page. [Panasonic alarm protocol] Select "ON" or "OFF" to determine whether or not to notify of an alarm occurrence by Panasonic alarm protocol when an alarm is detected. Default: OFF Note: When "ON" is selected, the alarm occurrence will be notified to the registered destination IP addresses in order (to IP address 1 first, to IP address 8 last). [Destination IP address] Enter the destination IP address of the Panasonic alarm protocol from the following. Up to 8 destination addresses can be registered. To notify by Panasonic alarm protocol when an alarm occurred, check the "Alarm" checkbox respective to the desired address. To notify by Panasonic alarm protocol when any of the following occurred, check the "Diag." checkbox respective to the desired address. • When notification of the remaining space of the SD memory card has been made (☞ page 21) • When the SD memory card became full • When mounting of the SD memory card failed To delete the registered address, click the [DEL] button respective to the desired address. Important: Confirm that the destination IP addresses are registered correctly. When a registered IP address does not exist, notification may be delayed. [Destination port] Select a destination port of the Panasonic alarm protocol from the following. Available port number: 1 - 65535 Default: 1818 [Retry times] Select a retry time of Panasonic alarm protocol. Available retry times: 1 - 30 Default: 2 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

34
Configure the settings relating to Panasonic alarm protocol [Panasonic alarm
protocol]
Click the [Notification] tab on the "Alarm setup" page. (
page 16)
The settings relating to Panasonic alarm protocol can be configured on this page.
[Panasonic alarm protocol]
Select "ON" or "OFF" to determine whether or not to
notify of an alarm occurrence by Panasonic alarm proto-
col when an alarm is detected.
Default:
OFF
Note:
When "ON" is selected, the alarm occurrence will be
notified to the registered destination IP addresses in
order (to IP address 1 first, to IP address 8 last).
[Destination port]
Select a destination port of the Panasonic alarm proto-
col from the following.
Available port number:
1 - 65535
Default:
1818
[Retry times]
Select a retry time of Panasonic alarm protocol.
Available retry times:
1 - 30
Default:
2
[Destination IP address]
Enter the destination IP address of the Panasonic alarm
protocol from the following. Up to 8 destination address-
es can be registered.
To notify by Panasonic alarm protocol when an alarm
occurred, check the "Alarm" checkbox respective to the
desired address.
To notify by Panasonic alarm protocol when any of the
following occurred, check the "Diag." checkbox respec-
tive to the desired address.
When notification of the remaining space of the SD
memory card has been made (
page 21)
When the SD memory card became full
When mounting of the SD memory card failed
To delete the registered address, click the [DEL] button
respective to the desired address.
Important:
Confirm that the destination IP addresses are regis-
tered correctly. When a registered IP address does
not exist, notification may be delayed.