Page 18 highlights

Installation Conditions 3.2.2 Calculating heat quantity As a courtesy to our customers, we have included the power formula for calculating air conditioning needs. For power consumption, allow 500 W = 500 VA per unit. Since most of the power consumed is transformed into heat, power consumption may be regarded as roughly equal to generated heat. 1 Conversion to calories [W] × 0.86 = [kcal/h] Heat generated per display: 500 W × 0.86 = 430 kcal/h 2 Conversion to British Thermal Units [W] × 3.41 = [BTU/h] Heat generated per unit: 500 W × 3.41 = 1705 BTU/h 3.2.3 Product mounting holes We recommend using mounting hardware available from Pioneer. If you use other mounting hardware, mount the hardware to the unit using the M8-bolt holes on the unit. Tighten the bolts with a torque between 50 kg/cm and 80 kg/ cm. Applying a torque beyond these limits may lead to internal component failure. Locations of usable mounting holes are shown below. b hole* Vent (fan) b hole* a Holes (4 places) b Holes (8 places) Attaching surface a holes Center line a holes This unit Installation bracket etc... a hole Bolt 12 mm to b hole 18 mm b hole* Center line Rear view diagram b hole* Screw provided with speaker unit (sold separately) Side view diagram * only for speaker unit Always use a minimum of 4 mounting holes that are evenly distributed on opposite sides of both the horizontal and vertical center lines. Use bolts that are long enough to be inserted 12 mm (1/2 in.) to 18 mm (11/16 in.) in to main unit from the attaching surface for a holes. Refer to the side view diagram in the above illustration. Do not block or cover vents on the rear panel. Take precautions to prevent the walls from being soiled by the Plasma Display's exhaust outlets. This unit incorporates glass components. Install only on flat surfaces. Always turn every bolt by hand two to three times then check to make sure the bolt is straight. You may tighten using a tool but do not over-tighten the bolts. Do not use loctight or similar bonding products. Please use M8 (P=1.25) bolts. DO NOT use any other type of bolt. The panel is attached using M8 x 4. For details, see the following page. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215

18
3.2.2 Calculating heat quantity
As a courtesy to our customers, we have included the power formula for calculating air conditioning needs.
For power consumption, allow 500 W = 500 VA per unit.
Since most of the power consumed is transformed into heat, power consumption may be regarded as roughly equal to
generated heat.
1
Conversion to calories
[W]
×
0.86 = [kcal/h]
Heat generated per display: 500 W
×
0.86 = 430 kcal/h
2
Conversion to British Thermal Units
[W]
×
3.41 = [BTU/h]
Heat generated per unit: 500 W
×
3.41 = 1705 BTU/h
3.2.3 Product mounting holes
We recommend using mounting hardware available from Pioneer. If you use other mounting hardware, mount the
hardware to the unit using the M8-bolt holes on the unit. Tighten the bolts with a torque between 50 kg/cm and 80 kg/
cm. Applying a torque beyond these limits may lead to internal component failure.
Locations of usable mounting holes are shown below.
Installation Conditions
Always use a minimum of 4 mounting holes that are evenly distributed on opposite sides of both the horizontal
and vertical center lines.
Use bolts that are long enough to be inserted 12 mm (1/2 in.) to 18 mm (11/16 in.) in to main unit from the
attaching surface for a holes. Refer to the side view diagram in the above illustration.
Do not block or cover vents on the rear panel.
Take precautions to prevent the walls from being soiled by the Plasma Display
s exhaust outlets.
This unit incorporates glass components. Install only on flat surfaces.
Always turn every bolt by hand two to three times then check to make sure the bolt is straight.
You may tighten using a tool but do not over-tighten the bolts.
Do not use
loctight
or similar bonding products.
Please use M8 (P=1.25) bolts. DO NOT use any other type of bolt.
The panel is attached using M8 x 4.
For details, see the following page.
12 mm to
18 mm
Rear view diagram
Side view diagram
b hole*
b hole*
b hole*
b hole*
Center line
a Holes (4 places)
b Holes (8 places)
This unit
a hole
Bolt
Screw provided with
speaker unit (sold
separately)
Vent (fan)
Attaching
surface
Installation
bracket etc...
b hole
a holes
a holes
Center line
* only for speaker unit