Poulan PRCS16i Owner Manual - Page 18

Error codes, TECHNICAL DATA

Page 18 highlights

Error codes The error codes help you do troubleshooting on the battery pack and/or the battery charger while it charges. Note: Look at the battery state of charge LED with the ribs of the battery pointed up to see the correct orientation of the LED lights. LED screen Possible faults Possible steps LED 1 is red and LED 4 is Internal fuse is blown green, battery pack does not charge or operate correctly in product Speak to an approved service center. LED 1 is red Irregular cell voltage Speak to an approved service center. LED 4 is green Battery pack is overcharged Remove the battery pack from the battery charger and install in the product. Operate the product. Battery charger may be defective. Speak to an approved service center. LED 1 is red and LED 2 is Battery pack failure green, battery pack does not charge or operate correctly in product Remove battery pack from the product. Do not charge. Battery pack is damaged and must be replaced. Speak to an approved service center. RED LED comes on, LED 2 is green and flashes during charging or when the battery pack is in the battery charger Internal battery tempature is too low or too high for charging Move the battery charger and battery pack to a location where the internal temperature of the battery pack can be between 5°C (41°F) and 45°C (113°F). RED LED flashes and LED 2 Internal battery tempera- The internal temperature in the battery must be between flashes green when the bat- ture is too low or too -15°C (5°F) and 70°C (158°F). The environment tempera- tery pack is installed. high ture in the battery pack is too low or too high. • If the battery pack is too cold from the ambient environment, move the battery pack and battery charger to a warm environment. • If the battery pack is too hot, especially after operation, move the battery pack and battery charger away from the hot environment. Motor specifications Motor type Motor voltage Motor power TECHNICAL DATA unit PRCS16i (BCS58VPR) V (DC) W Brushless 58 2000 18 319 - 002 - 17.11.2017

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Error codes
The error codes help you do troubleshooting on the
battery pack and/or the battery charger while it charges.
Note:
Look at the battery state of charge LED with the
ribs of the battery pointed up to see the correct
orientation of the LED lights.
LED screen
Possible faults
Possible steps
LED 1 is red and LED 4 is
green, battery pack does not
charge or operate correctly in
product
Internal fuse is blown
Speak to an approved service center.
LED 1 is red
Irregular cell voltage
Speak to an approved service center.
LED 4 is green
Battery pack is over-
charged
Remove the battery pack from the battery charger and in-
stall in the product. Operate the product. Battery charger
may be defective. Speak to an approved service center.
LED 1 is red and LED 2 is
green, battery pack does not
charge or operate correctly in
product
Battery pack failure
Remove battery pack from the product. Do not charge.
Battery pack is damaged and must be replaced. Speak to
an approved service center.
RED LED comes on, LED 2
is green and flashes during
charging or when the battery
pack is in the battery charger
Internal battery tempa-
ture is too low or too
high for charging
Move the battery charger and battery pack to a location
where the internal temperature of the battery pack can be
between 5°C (41°F) and 45°C (113°F).
RED LED flashes and LED 2
flashes green when the bat-
tery pack is installed.
Internal battery tempera-
ture is too low or too
high
The internal temperature in the battery must be between
-15°C (5°F) and 70°C (158°F). The environment tempera-
ture in the battery pack is too low or too high.
If the battery pack is too cold from the ambient envi-
ronment, move the battery pack and battery charger to
a warm environment.
If the battery pack is too hot, especially after operation,
move the battery pack and battery charger away from
the hot environment.
TECHNICAL DATA
unit
PRCS16i
(BCS58VPR)
Motor specifications
Motor type
Brushless
Motor voltage
V (DC)
58
Motor power
W
2000