ALARM OUT SET : Set the alarm out
View all Samsung SCP-3430HP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
setup ALARM IN SET : Select the alarm sensor operation between , and ALARM1 AUTO SET OFF . ALARM2 OFF ALARM OUT SET : Set the alarm out port matched to the alarm input port. ALARM3 ALARM4 ALARM5 OFF OFF OFF AUTO SET : Sets the pattern and scan ALARM6 OFF action for the corresponding alarm ALARM7 ALARM8 OFF OFF input. When the alarm is generated, the MOTION OFF camera moves to the preset position coupled to the corresponding alarm. Presets 1 ~ 8 are coupled with alarms 1 ~ 8 inputs respectively, and the preset 9 is coupled to the motion detection. The camera stops and remains in the corresponding preset position for the defined , and performs pattern or scan action defined by the . Setting to will discard with the pattern or scan action after moving to the preset position. - PATTERN 1 ~ 3 : Defined pattern action - HALF1 : Patterns 1 and 2 in serial action - HALF2 : Patterns 2 and 3 in serial action - WHOLE : Patterns 1, 2 and 3 in serial action - SCAN 1 ~ 4 : Predefined SCAN action M The is used as external switching signal if the is set to . AUX OUT CONTROL : Sets whether to sustain the alarm output despite of the AUX OUT CONTROL alarm generation or to output alarm out OUT1 OFF signal while the coupled alarm is alive. OUT2 OFF When selected , outputs alarm OUT3 OFF only if the alarm is generated. When selected , it always outputs alarm out signal despite of the alarm generation. 44_ setup