Samsung SNP-3371TH User Manual - Page 21

Baud Rate Settings, Communication Method Settings, Communication Response Settings, Termination

Page 21 highlights

● INSTALLATION & CONNECTION • Baud Rate Settings Select the transfer speed of a selected communication protocol. No. Baud Rate (BPS) 1 2400 2 4800 3 9600 4 19200 SW2-#5 ON ON OFF OFF SW2-#6 ON OFF OFF ON • Communication Method Settings Select a communication method for the camera. SW2-#7 Function Transfer Mode Switch ON RS-422(4Wire) OFF RS-485(2Wire) • Communication Response Settings Select a communication response method for the camera and controller: Response or No Response. SW2-#8 Function Response Mode Switch ON Response OFF No Response • Termination Settings To prevent the attenuation of communication signals between the camera and controller, the items at the end of line must be set up with the termination settings. Camera Input Position Termination of Longest Path On the Path SW2-#10 ON OFF SW2-#11 ON OFF M  The default value is shaded in each setting table.  To use a third party controller with this product, please contact our After-Sales Service or Technology Department. English _21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

English
_21
INSTALLATION & CONNECTION
Baud Rate Settings
Select the transfer speed of a selected communication protocol.
No.
Baud Rate (BPS)
SW2-#5
SW2-#6
1
2400
ON
ON
2
4800
ON
OFF
3
9600
OFF
OFF
4
19200
OFF
ON
Communication Method Settings
Select a communication method for the camera.
Function
ON
OFF
SW2-#7
Transfer Mode Switch
RS-422(4Wire)
RS-485(2Wire)
Communication Response Settings
Select a communication response method for the camera and controller: Response or No
Response.
Function
ON
OFF
SW2-#8
Response Mode Switch
Response
No Response
Termination Settings
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
Camera Input Position
SW2-#10
SW2-#11
Termination of Longest Path
ON
ON
On the Path
OFF
OFF
M
The default value is shaded in each setting table.
To use a third party controller with this product, please contact our After-Sales Service or