● INSTALLATION & CONNECTION • Baud Rate Settings Select the transfer speed of a selected communication protocol. No. Baud Rate (BPS) 1 2400 2 4800 3 9600 4 19200 SW2-#5 ON ON OFF OFF SW2-#6 ON OFF OFF ON • Communication Method Settings Select a communication method for the camera. SW2-#7 Function Transfer Mode Switch ON RS-422(4Wire) OFF RS-485(2Wire) • Communication Response Settings Select a communication response method for the camera and controller: Response or No Response. SW2-#8 Function Response Mode Switch ON Response OFF No Response • Termination Settings To prevent the attenuation of communication signals between the camera and controller, the items at the end of line must be set up with the termination settings. Camera Input Position Termination of Longest Path On the Path SW2-#10 ON OFF SW2-#11 ON OFF M The default value is shaded in each setting table. To use a third party controller with this product, please contact our After-Sales Service or Technology Department. English _21