Samsung SNP-3371TH User Manual - Page 71

PT limit

Page 71 highlights

● SETUP SCREEN To set the auto run This will perform the sequence operation that you have specified if no controller manipulation is made for a certain time. 1. Set in to . The menu screen will switch to the PTZ tracking and Auto execution menu screen. 2. Select an auto run mode. • Home : Automatically executes the operation to the home position. • Preset : Automatically executes the operation to the preset number. • Swing : Automatically executes the operation in Swing mode. • Group : Automatically executes the operation in Group mode. • Tour : Automatically executes the operation in Tour mode. • Trace : Automatically executes the operation in Trace mode. • Auto pan : Automatically executes the 360° rotation in the pan direction. PT limit You can specify restrictions on the pan or tilt function. 1. From the Setup menu, select the tab. 2. Click . 3. Decide if you want to limit the PT operations. If so, specify the details. • Pan / Tilt Limit : Select a mode to set between Pan limit and Tilt limit. - Use : Select whether to use limit in set mode. -[ ] : Start limit setting. -[ ] : Provide the start and end points. -[ ] : If you want to change the point setting, click this to return to the input dialog. English _71

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

English
_71
SETUP SCREEN
To set the auto run
This will perform the sequence operation that you have specified if no controller
manipulation is made for a certain time.
1.
Set <
Mode
> in <
Sequence setup
> to
<
Trace & Auto Run
>.
The menu screen will switch to the
PTZ tracking and Auto execution menu
screen.
2.
Select an auto run mode.
Home : Automatically executes the
operation to the home position.
Preset : Automatically executes the
operation to the preset number.
Swing : Automatically executes the operation in Swing mode.
Group : Automatically executes the operation in Group mode.
Tour : Automatically executes the operation in Tour mode.
Trace : Automatically executes the operation in Trace mode.
Auto pan : Automatically executes the 360° rotation in the pan direction.
PT limit
You can specify restrictions on the pan or tilt function.
1.
From the Setup menu, select the
<
Audio & Video (
)
> tab.
2.
Click <
PT limit
>.
3.
Decide if you want to limit the PT
operations. If so, specify the details.
Pan / Tilt Limit : Select a mode to set
between Pan limit and Tilt limit.
-
Use : Select whether to use limit in
set mode.
- [
] : Start limit setting.
- [
] : Provide the start and end points.
- [
] : If you want to change the point setting, click this to return to the
input dialog.