Sanyo PDG-DWL2500 RS232C Expand - Page 26
CF_SOURCE Command, CF_INPUT1 Command, CF_INPUT2 Command
UPC - 086483079061
View all Sanyo PDG-DWL2500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
PDG-DWL2500 Expand Serial Command Functional Specifications 8.6.2 CF_SOURCE Command Command "CF_SOURCE_%1"[CR] Input is Computer 1 "ANALOG" --------- Select Analog Input "YPBPR Select Component Input "SCART Select Scart Input "UP The same operation as pressing Up key or Left key "DN The same operation as pressing Down key or Right key Input is Computer 2 ""ANALOG" --------- Select Analog Input "UP" "DN" Projector accepts parameter "UP"/"DN" but no operation is made. %1 "HDMI Select HDMI Input Input is HDMI "UP" "DN" Projector accepts parameter "UP"/"DN" but no operation is made. Input is Video "VIDEO Select Composite Video Input "UP" "DN" Projector accepts parameter "UP"/"DN" but no operation is made. Input is S-video S-VIDEO Select S-video Input "UP" "DN" Projector accepts parameter "UP"/"DN" but no operation is made. Details Select Source of currently selected Input When Input specified by %1 is inappropriate for selected Input, the projector returns "101" and the command is not executed. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.6.3 CF_INPUT1 Command Command "CF_INPUT1_%1_"[CR] "ANALOG Select Analog RGB Input %1 "YPBPR Select Component "SCART Select SCART Details Select Input - Computer 1 and source specified in %1 at once. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.6.4 CF_INPUT2 Command Command "CF_INPUT2_%1_"[CR] %1 "ANALOG Select Analog RGB Input Details Select Input - Computer 2 and source specified in %1 at once. This command is available in normal Power ON status. Projector returns "101" by selecting Computer 2 while Monitor out is selected in Terminal menu. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 25/72