Sanyo PDG-DWL2500 RS232C Expand - Page 41

CF_P-MANETIME Command, 10.20 CF_ON-STA Command, 10.21 CF_CCAPTIONDISP Command, 10.22,

Page 41 highlights

PDG-DWL2500 Expand Serial Command Functional Specifications Response after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Unacceptable "Error Code"[CR] 8.10.19 CF_P-MANETIME Command Command "CF_P-MANETIME_%1"[CR] "01" ~ "30 Directly select setting time by the minute "UP Plus one minute (01 → 02 → → 30 → 01) "DN Minus one minute(30 → 29 → → 01 → 30) Details Set Power Management time The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.20 CF_ON-STA Command Command "CF_ON STA_%1"[CR] "ON Set Direct on active "OFF Set Direct on inactive %1 "UP Switch setting (On → Off → On → ) "DN Switch setting (On → Off → On → ) Note) "UP" and "DN" behave the same. Details Set/Cancel Power ON Start The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.21 CF_CCAPTIONDISP Command Command "CF_CCAPTIONDISP_%1"[CR] "OFF Select Off "CC1 Select CC1 %1 "CC2 Select CC2 "CC3 Select CC3 "CC4 Select CC4 Details Select channel of Closed caption. The status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF. This command is available in normal Power ON status. Response Note)Closed caption is available under conditions below; Entered signal is appropriate (Video, NTSC signal of S-video). Acceptable "000"[CR] Unacceptable "Error Code"[CR] 8.10.22 CF_CCAPTIONCOLOR Command Command "CF_CCAPTIONCOLOR_%1"[CR] %1 "COLOR" ------- Select Color 40/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PDG-DWL2500
Expand Serial Command Functional Specifications
40/72
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.19 CF_P-MANETIME Command
Command
“CF_P-MANETIME_%1”[CR]
��
“01” ~ ”30” ----------------------- Directly select setting time by the minute
“UP” ------------------------------- Plus one minute (01
02
���
30
01)
“DN” ------------------------------- Minus one minute(30
29
���
01
30)
Details
Set Power Management time
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.20 CF_ON-STA Command
Command
“CF_ON
STA_%1”[CR]
%1
“ON” --------------------------- Set Direct on active
“OFF” ------------------------- Set Direct on inactive
“UP” --------------------------- Switch setting (On
Off
On
���
)
“DN” --------------------------- Switch setting (On
Off
On
���
)
Note) “UP” and “DN” behave the same.
Details
Set/Cancel Power ON Start
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.21 CF_CCAPTIONDISP Command
Command
“CF_CCAPTIONDISP_%1”[CR]
%1
“OFF” ------------- Select Off
“CC1” ------------- Select CC1
“CC2” ------------- Select CC2
“CC3” ------------- Select CC3
“CC4” ------------- Select CC4
Details
Select channel of Closed caption.
The status set with this command is stored in EEPROM and its setting is effective
even after ALL is OFF.
This command is available in normal Power ON status.
Note)Closed caption is available under conditions below;
Entered signal is appropriate (Video, NTSC signal of S-video).
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
8.10.22
CF_CCAPTIONCOLOR Command
Command
“CF_CCAPTIONCOLOR_%1”[CR]
%1
“COLOR” ------- Select Color