Sanyo PDG-DWL2500 RS232C Expand - Page 51

PC Adjust Status Read Command, CR_FSYNC Command, CR_TDOTS Command, CR_CLAMP Command, CR_H - POS

Page 51 highlights

PDG-DWL2500 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC"[CR] Details Get Fine Sync value Response Acceptable %a "000_%a"[CR] "0000"~"0031" Unacceptable "Error Code"[CR] 9.5.2 CR_TDOTS Command Command "CR_TDOTS"[CR] Details Get Total Dots value Acceptable "000_%a"[CR] "nnnn"~"mmmm" Response %a (nnnn = Display Dots + Horizontal Position) (mmmm= Maximum value depends on input signal) Unacceptable "Error Code"[CR] 9.5.3 CR_CLAMP Command Command "CR_CLAMP"[CR] Details Get Clamp value Acceptable "000_%a"[CR] Response %a "0001"~"nnnn" ("nnnn" depends on input signal) Unacceptable "Error Code"[CR] 9.5.4 CR_H - POS Command Command "CR_H - POS"[CR] Details Get Horizontal Position value Acceptable "000_%a"[CR] Response %a "0000"~"nnnn" (nnnn = Total Dots - Display Dots) Unacceptable "Error Code"[CR] 9.5.5 CR_V - POS Command Command "CR_V - POS"[CR] Details Get Vertical Position value Acceptable "000_%a"[CR] Response %a "0000"~"nnnn" (nnnn = Total Line - Display Line) Unacceptable "Error Code"[CR] 50/72

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

PDG-DWL2500
Expand Serial Command Functional Specifications
50/72
9.5
PC Adjust Status Read Command
9.5.1
CR_FSYNC Command
Command
"CR_FSYNC”[CR]
Details
Get Fine Sync value
Acceptable
“000_%a”[CR]
%a
“0000”~“0031”
Response
Unacceptable
“Error Code”[CR]
9.5.2
CR_TDOTS Command
Command
“CR_TDOTS”[CR]
Details
Get Total Dots value
Acceptable
“000_%a”[CR]
%a
“nnnn”~“mmmm”
(nnnn = Display Dots + Horizontal Position)
(mmmm= Maximum value depends on input signal)
Response
Unacceptable
“Error Code”[CR]
9.5.3
CR_CLAMP Command
Command
“CR_CLAMP”[CR]
Details
Get Clamp value
Acceptable
“000_%a”[CR]
%a
“0001”~“nnnn”
(“nnnn” depends on input signal)
Response
Unacceptable
“Error Code”[CR]
9.5.4
CR_H – POS Command
Command
“CR_H
-
POS”[CR]
Details
Get Horizontal Position value
Acceptable
“000_%a”[CR]
%a
“0000”~“nnnn”
(nnnn = Total Dots - Display Dots)
Response
Unacceptable
“Error Code”[CR]
9.5.5
CR_V – POS Command
Command
“CR_V
-
POS”[CR]
Details
Get Vertical Position value
Acceptable
“000_%a”[CR]
%a
“0000”~“nnnn”
(nnnn = Total Line - Display Line)
Response
Unacceptable
“Error Code”[CR]