Sanyo PLC-HP7000L RS232C Basic - Page 16
Power Management Cancel Command
View all Sanyo PLC-HP7000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
PLC-HP7000L Basic Serial Command Functional Specifications 6.28 POWER MANAGEMENT CANCEL Command Command "C2B" [CR] Detail Set Power Management function to off status This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.29 POWER MANAGEMENT READY2 Command Command "C2C" [CR] Detail Set Power Management function to ready2 status This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.30 POWER MANAGEMENT SHUTDOWN Command Command "C2E" [CR] Detail Set Power Management function to Shutdown mode. This status is stored in EEPROM and retained regardless of Power OFF/ON operation. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.31 D.ZOOM + Command Command "C30" [CR] Detail Enter Digital Zoom mode and expand image size This command works the same way as "D.ZOOM ▲" button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.32 D.ZOOM - Command Command "C31" [CR] Detail Enter Digital Zoom mode and reduce image size This command works the same as "D.ZOOM ▼" button of the remote control. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 6.33 INPUT 3 VIDEO Command Command "C33" [CR] Detail Select Video input in Input 3. Although projector returns "OK", Input search is not executed with this command while Input button is set to Mode2 or Mode3. Response Acceptable [ACK] [CR] Unacceptable "?" [CR] 16/27