Sanyo PLC-HP7000L RS232C Basic - Page 27

Temp Read Command, 9 Lamp Mode Read Command

Page 27 highlights

PLC-HP7000L Basic Serial Command Functional Specifications 7.8 Temp Read Command Command "CR6" [CR] Detail Get the information of temperature inside a projector. With several built-in temperature sensors, it can get all the temperatures at once. Acceptable "%1 _ %2 _ %3" [CR] %1 = Temp. of sensor 1 %2 = Temp. of sensor 2 %3 = Temp. of sensor 3 Temperature data basic format is "_00.0". ("_" indicates a space) When the temperature goes under 0, it starts with "-" instead of a %1 space like "-05.5" [CR]. Response %2 When no temperature data returns due to hardware problems, it %3 starts with "E" like"E00.0" [CR]. With several built-in temperature sensors, the projector returns the values in succession. "_31.5_ _35.2_ 33.4 " [CR] The first sensor's data is followed by one space and afterwards the second sensor's data. Unacceptable "?" [CR] 7.9 Lamp Mode Read Command Command "CR7" [CR] Detail Get lamp mode. In the projector with single lamp, get ON/OFF status of the lamp Acceptable "%1" [CR] Response %1 "00" [CR] = Lamp is ON. "01" [CR] = Lamp is OFF. Unacceptable "?" [CR] 27/27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

PLC-HP7000L Basic Serial Command Functional Specifications
27/27
7.8 Temp Read Command
Command
“CR6” [CR]
Detail
Get the information of temperature inside a projector.
With several built-in temperature sensors, it can get all the temperatures at once.
Acceptable
“%1 _ %2 _ %3” [CR]
%1
%2
%3
%1 = Temp. of sensor 1
%2 = Temp. of sensor 2
%3 = Temp. of sensor 3
Temperature data basic format is “_00.0”. (“_” indicates a space)
When the temperature goes under 0, it starts with “-” instead of a
space like “-05.5” [CR].
When no temperature data returns due to hardware problems, it
starts with “E” like”E00.0” [CR].
With several built-in temperature sensors, the projector returns
the values in succession.
“_31.5_ _35.2_ 33.4 ” [CR]
The first sensor’s data is followed by one space and afterwards
the second sensor’s data.
Response
Unacceptable
“?” [CR]
7.9 Lamp Mode Read Command
Command
“CR7” [CR]
Detail
Get lamp mode.
In the projector with single lamp, get ON/OFF status of the lamp
Acceptable
“%1” [CR]
%1
“00” [CR] = Lamp is ON.
“01” [CR] = Lamp is OFF.
Response
Unacceptable
“?” [CR]