Sanyo PLC-HP7000L RS232C Basic - Page 24

[CR], 28 [CR], 88 [CR], 24 [CR]

Page 24 highlights

PLC-HP7000L Basic Serial Command Functional Specifications ・ "10" [CR] Status: Power Failure When the power supply voltage inside the projector reaches abnormal status, the projector is automatically turned off. ※ Abnormal power supply voltage includes; - Filter abnormal status - Shutter abnormal status The projector returns "10" [CR], which indicates it enters Power OFF status due to Power Failure. In this case Fan also stops unlike Cooling Down status. ・ "28" [CR] Status: Cooling Down in process due to Abnormal Temperature When the inside temperature rises abnormally high, it automatically starts Cooling Down operation. The projector returns "28" [CR]. Even if the temperature goes down during this process, the given Cooling Down process is conducted. ・ "88" [CR] Status: Standby after Cooling Down due to Abnormal Temperature When the status becomes Standby after the temperature goes down by Cooling Down operation invoked due to Abnormal Temperature, the projector returns "88" [CR]. This indicates Abnormal Temperature caused turning to Standby status. This status continues until the next operation is started; when Power On is executed, the projector clears the information of Abnormal Temperature and normal operation starts. ・ "24" [CR] Status: Power-Save Cooling Down in process This indicates Power Management in the Setting menu is enabled and Power-Save Cooling Down operation is in process. During this time, any Functional Execution Command is invalid. In this Power-Save Cooling Down function, the status moves to Power Save after the given Cooling down operation. Status: No signal Response: "00" Power-Save Cooling Down "24" Power Save "04" No signal status has passed for the time set by power management timer After about 90 sec. 24/27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27

PLC-HP7000L Basic Serial Command Functional Specifications
24/27
“10” [CR]
Status: Power Failure
When the power supply voltage inside the projector reaches abnormal status, the projector
is automatically turned off.
Abnormal power supply voltage includes;
-
Filter abnormal status
-
Shutter abnormal status
The projector returns “10” [CR], which indicates it enters Power OFF status due to Power
Failure.
In this case Fan also stops unlike Cooling Down status.
“28” [CR]
Status: Cooling Down in process due to Abnormal Temperature
When the inside temperature rises abnormally high, it automatically starts Cooling Down
operation.
The projector returns “28” [CR].
Even if the temperature goes down during this process, the given Cooling Down process is
conducted.
“88” [CR]
Status: Standby after Cooling Down due to Abnormal Temperature
When the status becomes Standby after the temperature goes down by Cooling Down
operation invoked due to Abnormal Temperature, the projector returns “88” [CR]. This
indicates Abnormal Temperature caused turning to Standby status.
This status continues until the next operation is started; when Power On is executed, the
projector clears the information of Abnormal Temperature and normal operation starts.
“24” [CR]
Status: Power-Save Cooling Down in process
This indicates Power Management in the Setting menu is enabled and Power-Save
Cooling Down operation is in process.
During this time, any Functional Execution Command is invalid.
In this Power-Save Cooling Down function, the status moves to Power Save after the given
Cooling down operation.
Status
No signal
Power-Save Cooling Down
Power Save
Response
“00”
“24”
“04”
No signal status has passed for the time
set by power management timer
After about 90 sec.