Sanyo PLC-HP7000L RS232C Basic - Page 26
Input Mode Read Command, 6 Lamp Time Read Command, 7 Setting Read Command
View all Sanyo PLC-HP7000L manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
PLC-HP7000L Basic Serial Command Functional Specifications 7.5 Input Mode Read Command Command "CR1" [CR] Detail Get currently selected Input No. Acceptable "%1" [CR] "1" = Input 1 is selected. Response %1 "2" = Input 2 is selected. "3" = Input 3 is selected. "4" = Input 4 is selected.(only for Networking-capable models) Unacceptable "?" [CR] 7.6 Lamp Time Read Command Command "CR3" [CR] Detail Get total lamp running hours. *return lamp operating time multiplied by the given coefficient (not actual used time) Acceptable "%1" [CR] Display Lamp running hours with 5 digit numbers. Response %1 Example: "00410" [CR 410 hours Unacceptable "?" [CR] 7.7 Setting Read Command Command "CR4" [CR] Detail Get screen setting status such as Ceiling/Rear. Acceptable "%1" [CR] "11" [CR] = Normal Screen Setting "10" [CR] = Picture is top/bottom reversed. (Status: Rear & Ceiling Response %1 ON) "01" [CR] = Picture is left/right reversed. (Status: Rear ON) "00" [CR] = Picture is top/bottom and left/right reversed. (Status: Ceiling ON) Unacceptable "?" [CR] 26/27