Sharp AF-05CML Service Manual - Page 18

Running Condition

Page 18 highlights

AF-05CML RUNNING CONDITION Note: 1. Select mode of the Running Condition of a Room Air Conditioner. SELECTOR ...HIGH COOL THERMOSTAT 64˚F 2. Data of Performance Curve is measured between 40%RH and 70%RH. If you measure the Room Air Conditioner above or below this rating, the data may miss the range of the performance curve. 3. Outlet air temp. is influenced by the method of measurement. Measurement examples are shown. 4. Use power input data when checking the Running Condition. RUNNING CONDITION FOR PERFORMANCE CURVE 40%RH 600 Power input (W) 500 70%RH 400 300 40%RH 5 Line current(Amp.) 4 70%RH Outlet air temp˚C (˚F) 3 30 (86) 20 (68) 10 (50) 25 (77) 70%RH 40%RH 30 35 (86) (95) Outside air temp.˚C (˚F) 40 (104) 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

18
AF-05CML
RUNNING CONDITION
Note:
1.
Select mode of the Running Condition of a Room Air Conditioner.
SELECTOR
....................................................................................................
HIGH COOL
THERMOSTAT
..............................................................................................
64˚F
2.
Data of Performance Curve is measured between 40%RH and 70%RH.
If you measure the Room Air Conditioner above or below this rating, the data may miss the range of the
performance curve.
3.
Outlet air temp. is influenced by the method of measurement. Measurement examples are shown.
4.
Use power input data when checking the Running Condition.
RUNNING CONDITION FOR
PERFORMANCE CURVE
Outside air temp.˚C (˚F)
Outlet air temp˚C (˚F)
25
30
35
(77)
(86)
(95)
(104)
40
10
20
30
(50)
(68)
(86)
3
4
5
400
300
500
Line current(Amp.)
Power input (W)
600
40%RH
70%RH
70%RH
40%RH
40%RH
70%RH