17. Remove the caseing. 18. Unscrew the 4 screws holding fan motor. AF-05CML DISASSEMBLING THE CONTROL BOX 1 Unscrew the 2 screws holding the control box cover. CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR AND RUNNING CAPACITOR BEFORE TOUCHING THOSE CAPACITORS OR OTHER COMPONENTS OR WIRING. 3 Unscrew the 3 screw holding the selector switch and thermostat. And take off the wiring connector of the compressor cord, the fan motor cord and the power supply cord. 2 Cut the wire fixing bands holding the fan motor lead 4 Unscrew the 1 screw holding the capacitor clamp and wires, the compressor cord and the power supply cord. the fan motor capacitor, and take off each connector. And unscrew 2 earth screws. 9
![](/manual_guide/products/sharp-af05cml-service-manual-f601367/9.png)
9
AF-05CML
17. Remove the caseing.
18. Unscrew the 4 screws holding fan motor.
DISASSEMBLING
THE
CONTROL
BOX
1
Unscrew the 2 screws holding the control box cover.
CAUTION:
DISCHARGE THE FAN MOTOR CAPACITOR
AND RUNNING CAPACITOR BEFORE
TOUCHING THOSE CAPACITORS OR OTHER
COMPONENTS OR WIRING.
2
Cut the wire fixing bands holding the fan motor lead
wires, the compressor cord and the power supply cord.
3
Unscrew the 3 screw holding the selector switch and
thermostat. And take off the wiring connector of the
compressor cord, the fan motor cord and the power
supply cord.
4
Unscrew the 1 screw holding the capacitor clamp and
the fan motor capacitor, and take off each connector.
And unscrew 2 earth screws.