Sharp AF-05CML Service Manual - Page 9

Disassembling, Control

Page 9 highlights

17. Remove the caseing. 18. Unscrew the 4 screws holding fan motor. AF-05CML DISASSEMBLING THE CONTROL BOX 1 Unscrew the 2 screws holding the control box cover. CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR AND RUNNING CAPACITOR BEFORE TOUCHING THOSE CAPACITORS OR OTHER COMPONENTS OR WIRING. 3 Unscrew the 3 screw holding the selector switch and thermostat. And take off the wiring connector of the compressor cord, the fan motor cord and the power supply cord. 2 Cut the wire fixing bands holding the fan motor lead 4 Unscrew the 1 screw holding the capacitor clamp and wires, the compressor cord and the power supply cord. the fan motor capacitor, and take off each connector. And unscrew 2 earth screws. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

9
AF-05CML
17. Remove the caseing.
18. Unscrew the 4 screws holding fan motor.
DISASSEMBLING
THE
CONTROL
BOX
1
Unscrew the 2 screws holding the control box cover.
CAUTION:
DISCHARGE THE FAN MOTOR CAPACITOR
AND RUNNING CAPACITOR BEFORE
TOUCHING THOSE CAPACITORS OR OTHER
COMPONENTS OR WIRING.
2
Cut the wire fixing bands holding the fan motor lead
wires, the compressor cord and the power supply cord.
3
Unscrew the 3 screw holding the selector switch and
thermostat. And take off the wiring connector of the
compressor cord, the fan motor cord and the power
supply cord.
4
Unscrew the 1 screw holding the capacitor clamp and
the fan motor capacitor, and take off each connector.
And unscrew 2 earth screws.