Sharp AF-05CML Service Manual - Page 2
Specifications
![]() |
View all Sharp AF-05CML manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
AF-05CML SPECIFICATIONS Models Cooling capacity BTU/h Moisture removal Pints/h ELECTRICAL DATA Phase Rared frequency Hz Rated voltage Volts Rated current Amps Rated input Watts Power factor % EER BTU/Wh COMPRESSOR Type Model, Motor output REFRIGERANT SYSTEM Evaporator Condenser Control O.D. x I.D. x Length x Q'ty(mm) (Capillary tube) Refrigerant volume R-22(OZ) (Factory change) NET DIMENSIONS Width Height Depth inches(mm) Net Weight lbs GROSS DIMENSIONS Width Height Depth inches(mm) Gross Weight lbs FAN SYSTEM Indoor side(Evaporator) Outdoor side(Condenser) Air flow rate(indoor side) CFM OTHERS Safety devices Air filter Power cord length ft Power plug type ELECTRICAL PARTS Running capacitor Fan capacitor Selector switch Thermistor Fan motor Overload relay AF-05CML 5000 1.0 Single 60 115 4.6 500 95 10.0 (Hermetically sealed rotary type) RM5455GQ86, 400W Louver fin, Grooved tube, 7mm, Hair pin Louver fin, Grooved tube, 7mm, Hair pin 2.7 x 1.1 x 400 x 1 8.5 17-23/32(450) x 14-9/16(370) x 14-7/8(378) 47 20-7/8(530) x 18-1/8(460) x 18-3/8(467) 52 Centrifugal fan Propeller fan High / Med / Low 195 / 175 / 150 Compressor: Overload relay Fan motor: Internal thermal protector Polypropylene net 6.0 125V, 10A 250V-40µF 250V-6µF 2109 No. APPLI- COLD . CAUTION CUT-IN MM1-A001 Cooling 66.2˚F OBM-2016K1 (MLA998) MRA99484 COLD CUT-OUT 61.7˚F WARM CUT-IN 86.0˚F WARM CUT-OUT 82.5˚F 2
![](/manual_guide/products/sharp-af05cml-service-manual-f601367/2.png)