Sharp PN-C861H PN-C751H PN-C861H Operation Manual - Page 23

RS-232C command table, Power control/Input mode selection, Picture menu, Sound menu

Page 23 highlights

Controlling the Monitor with a computer (RS-232C) RS-232C command table How to read the command table Command: Direction: Parameter: Reply: Command field (See page 21.) W When the "Parameter" is set in the parameter field (see page 21), the command functions as described under "Control/Response Contents". R The returned value indicated under "Reply" can be obtained by setting "????" or " ?" in the parameter field. (See page 21.) Parameter field (See page 21.) Response (Returned value) TIPS • In the standby mode, the only command that is used is Power control. Power control/Input mode selection Power control Function Command Direction POWR W R Parameter 0 1 Input mode selection INPS W 0 2 3 4 10 13 18 21 24 R Reply Control/Response contents Switches to standby mode. Returns from standby mode. 0 Standby mode 1 Normal mode Toggle change for input mode. VGA YPBPR AV HDMI 1 HDMI 2 HDMI 3 OPS "ERR" when nothing is attached in the expansion slot. APPLICATION 2 VGA 3 YPBPR 4 AV 10 HDMI 1 13 HDMI 2 18 HDMI 3 21 OPS 24 APPLICATION Picture menu Function BRIGHT SIZE (Screen size selection) Command Direction VLMP WR WIDE W WR Parameter 0-100 0 1-5 Reply Control/Response contents 0-100 "ERR" when Auto and Energy Saving are in effect. 0 Toggle change for input mode. 1-5 1: 16:9, 2: Dot by Dot, 3: 4:3, 4: Zoom1, 5: Zoom2 Sound menu VOLUME MUTE AUDIO Function Command VOLM MUTE Direction WR WR Parameter 0-100 0-1 Reply 0-100 0-1 0: OFF, 1: ON Control/Response contents 23 E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

23
E
RS-232C command table
How to read the command table
Command:
Command field (See page 21.)
Direction:
W When the “Parameter” is set in the parameter field (see page 21), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????” or “
?” in the
parameter field. (See page 21.)
Parameter:
Parameter field (See page 21.)
Reply:
Response (Returned value)
TIPS
In the standby mode, the only command that is used is Power control.
Power control/Input mode selection
Function
Command
Direction
Parameter
Reply
Control/Response contents
Power control
POWR
W
0
Switches to standby mode.
1
Returns from standby mode.
R
0
Standby mode
1
Normal mode
Input mode selection
INPS
W
0
Toggle change for input mode.
2
VGA
3
YPBPR
4
AV
10
HDMI 1
13
HDMI 2
18
HDMI 3
21
OPS
“ERR” when nothing is attached in the expansion slot.
24
APPLICATION
R
2
VGA
3
YPBPR
4
AV
10
HDMI 1
13
HDMI 2
18
HDMI 3
21
OPS
24
APPLICATION
Picture menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
BRIGHT
VLMP
WR
0-100
0-100
“ERR” when Auto and Energy Saving are in effect.
SIZE (Screen size selection)
WIDE
W
0
0
Toggle change for input mode.
WR
1-5
1-5
1: 16:9, 2: Dot by Dot, 3: 4:3, 4: Zoom1, 5: Zoom2
Sound menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
VOLUME
VOLM
WR
0-100
0-100
MUTE AUDIO
MUTE
WR
0-1
0-1
0: OFF, 1: ON