Sharp XR-1XDM XR-1S , XR-1X Operation Manual - Page 61

Resetting the Lamp Timer

Page 61 highlights

4 Remove the lamp unit. • Loosen the securing screws from the lamp unit. Hold the lamp unit by the handle and pull it in the direction of the arrow. At this time, keep the lamp unithorizontal and do not tilt it. Handle 5 Insert the new lamp unit. • Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. Securing screws 6 Replace the lamp unit cover. • Align the tab on the lamp unit cover (1)and place it while pressing the tab (2) to close it. Then tighten the user service screw (3) to secure the lamp unit cover. Info • If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector. Resetting the Lamp Timer Reset the lamp timer after replacing the lamp. User service screw (for lamp unit cover) Info • Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode. 1 Connect the power cord. • Plug the power cord into the AC socket of the projector. AC socket ON/STANDBY button ENTER button 2 Reset the lamp timer. • While simultaneously holding down UMENU, TENTER and Y on the projector, press and SON/STANDBY on the projector. • "LAMP 0000H" is displayed, indicating that the lamp timer is reset. Y button MENU button 57 Appendix

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

57
Appendix
Remove the lamp unit.
• Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp
unithorizontal and do not tilt it.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Insert the new lamp unit.
• Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
Replace the lamp unit cover.
• Align the tab on the lamp unit cover
(
1
)and place it while pressing the tab
(
2
) to close it. Then tighten the user ser-
vice screw (
3
) to secure the lamp unit
cover.
4
5
6
Connect the power cord.
• Plug the power cord into the AC socket
of the projector.
Reset the lamp timer.
• While simultaneously holding down
U
MENU,
T
ENTER and
Y
on the pro-
jector, press and
S
ON/STANDBY on the
projector.
• “LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
• Make sure to reset the lamp timer only when
replacing the lamp. If you reset the lamp timer
and continue to use the same lamp, this may
cause the lamp to become damaged or ex-
plode.
1
2
Info
AC socket
Securing screws
Handle
User service
screw (for
lamp unit
cover)
ON/STANDBY button
ENTER button
MENU button
Y
button
• If the lamp unit and lamp unit cover are
not correctly installed, the power will not
turn on, even if the power cord is con-
nected to the projector.
Info