Sony GDM-500PS Operating Instructions - Page 19

Power Saving Function, Damper Wires, Plug & Play - trinitron

Page 19 highlights

Getting STteacrhtendical Features Power Saving Function This monitor meets the power-saving guidelines set by VESA and Energy Star, as well as the more stringent NUTEK . If the monitor is connected to a computer or video graphics board that is VESA DPMS (Display Power Management Signaling) compliant, the monitor will automatically reduce power consumption in three stages as shown below. You can set the delay time before the monitor enters the power saving mode using the OSD. Set the time according to "Setting the power saving delay time" on page 16. Note If no video signal is input to the monitor, the "NO INPUT SIGNAL" message (page 20) appears. After the delay time has passed, the power saving function automatically puts the monitor into the active-off mode and the u indicator lights up orange. Once the horizontal and vertical sync signals are detected, the monitor automatically resumes its normal operation mode. Power consumption mode 1 Normal operation Screen active Horizontal sync signal present Vertical Power consumption sync signal present ≤ 145 W (GDM-500PS) ≤ 125 W (GDM-400PS) Recovery time u indicator - Green 2 Standby (1st mode) blank absent present Approx. 72 W (GDM-500PS) Approx. 3 sec. Approx. 65 W (GDM-400PS) Green and orange alternate 3 Suspend (2nd mode) blank present absent Approx. 8 W Approx. 3 sec. Green and orange alternate 4 Active-off (3rd mode) blank 5 Power-off - absent - absent - Approx. 4 W 0 W Approx. 10 sec. Orange - Off EN Damper Wires Plug & Play F When viewing a white background, very thin horizontal lines may be visible on the screen as shown below. These lines are the shadows of the damper wires and are characteristic of CRTs that use aperture grilles. The wires are attached to the aperture grille on the inside of the Trinitron tube and prevent the vibration of the aperture grille. Damper wires This monitor complies with the DDC™1, DDC2B, DDC2AB ES and DDC2B+ Display Data Channel (DDC) standards of VESA. When a DDC1 host system is connected, the monitor C synchronizes with the V. CLK in accordance with the VESA standards and outputs the EDID (Extended Display Identification Data) to the data line. When a DDC2B, DDC2AB or DDC2B+ host system is connected, the monitor automatically switches to the appropriate standard. DDC™ is a trademark of the Video Electronics Standard Association. Note When using Windows 95/98, the DDC standard does not apply to the 5 BNC connectors. If you use the DDC standard, connect the HD15 connector to the computer with the supplied video signal cable. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63

19
Technical Features
EN
Power Saving Function
This monitor meets the power-saving guidelines set by
VESA and Energy Star, as well as the more stringent
NUTEK .
If the monitor is connected to a computer or video graphics
board that is VESA DPMS (Display Power Management
Signaling) compliant, the monitor will automatically reduce
power consumption in three stages as shown below.
1
2
3
4
5
Recovery time
Approx. 3 sec.
Approx. 3 sec.
Approx. 10 sec.
u
indicator
Green
Green and orange
alternate
Green and orange
alternate
Orange
Off
Power consumption
mode
Normal operation
Standby (1st mode)
Suspend (2nd mode)
Active-off (3rd mode)
Power-off
Screen
active
blank
blank
blank
Horizontal
sync signal
present
absent
present
absent
Vertical
sync signal
present
present
absent
absent
You can set the delay time before the monitor enters the
power saving mode using the OSD. Set the time according
to “Setting the power saving delay time” on page 16.
Note
If no video signal is input to the monitor, the “NO INPUT
SIGNAL” message (page 20) appears.
After the delay time has
passed, the power saving function automatically puts the monitor
into the active-off mode and the
u
indicator lights up orange. Once
the horizontal and vertical sync signals are detected, the monitor
automatically resumes its normal operation mode.
Damper Wires
When viewing a white background, very thin horizontal
lines may be visible on the screen as shown below. These
lines are the shadows of the damper wires and are
characteristic of CRTs that use aperture grilles. The wires
are attached to the aperture grille on the inside of the
Trinitron tube and prevent the vibration of the aperture
grille.
Damper wires
Plug & Play
This monitor complies with the DDC
1, DDC2B, DDC2AB
and DDC2B+ Display Data Channel (DDC) standards of
VESA.
When a DDC1 host system is connected, the monitor
synchronizes with the V. CLK in accordance with the VESA
standards and outputs the EDID (Extended Display
Identification Data) to the data line.
When a DDC2B, DDC2AB or DDC2B+ host system is
connected, the monitor automatically switches to the
appropriate standard.
DDC
is a trademark of the Video Electronics Standard
Association.
Note
When using Windows 95/98, the DDC standard does not apply to
the 5 BNC connectors. If you use the DDC standard, connect the
HD15 connector to the computer with the supplied video signal
cable.
Power consumption
145 W (GDM-500PS)
125 W (GDM-400PS)
Approx. 72 W (GDM-500PS)
Approx. 65 W (GDM-400PS)
Approx. 8 W
Approx. 4 W
0 W