Sony UP895 Service Manual - Page 23

Electrical Alignment, 3-1. AGC Adjustment, 3-2. Video Level Adjustment

Page 23 highlights

Section 3 Electrical Alignment [Equipment Required] . Oscilloscope . Digital voltmeter . 10 steps signal generator Tektronix 1410 or equivalents (For NTSC signal) Tektronix 1411 or equivalents (For PAL signal) 3-1. AGC Adjustment Machine condition for adjustment . Input signal: 10 steps signal . No monitor is connected. . Set rear panel DIP switch 9 to up. (AGC-ON) Specification TP5 (AMP IN)/MA-99 (C-3) Output waveform Vs Adjustments AGC REF adjustment 1RV3/MA-99 (C-2) AGC GAIN adjustment 1RV2/MA-99 (C-2) MA-99 Procedure 1. Input a 10 steps signal and set DIP switch != to DOWN. Adjust RV3 (AGC REF) so that Vs is 700 mV. 2. Set DIP switch != to UP and adjust RV2 (AGC GAIN) so that Vs is 630 mV. . Adjust so that Vs is 700 mV when AGC is ON and 75 Z terminator is on. . Adjust so that Vs is 630 mV when AGC is ON and 75 Z terminator is off. 1RV3 1RV2 TP5 3-2. Video Level Adjustment Machine condition for adjustment Specification . Input signal: 10 steps signal . In case, monitor is not connected, set DIP switch != on the rear panel to ON, if connected, set to OFF. . Adjust RV4 (AGC OFF CONT) using 10 steps signal input. TP5 (AMP IN)/MA-99 (C-3) Output waveform 1.0 V Adjustments AGC OFF CONT adjustment 1RV4/MA-99 (C-2) MA-99 Adjust so that video signal level is 1.0 V. 1RV4 TP5 UP-895/(E) 3-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

3-1
UP-895/(E)
[Equipment Required]
.
Oscilloscope
.
Digital voltmeter
.
10 steps signal generator
Tektronix 1410 or equivalents (For NTSC signal)
Tektronix 1411 or equivalents (For PAL signal)
3-1.
AGC Adjustment
Section 3
Electrical Alignment
Machine condition for adjustment
.
Input signal: 10 steps signal
.
No monitor is connected.
.
Set rear panel DIP switch
9
to up.
(AGC-ON)
Procedure
1.
Input a 10 steps signal and set DIP
switch
!=
to DOWN.
Adjust RV3 (AGC
REF) so that Vs is 700 mV.
2.
Set DIP switch
!=
to UP and adjust RV2
(AGC GAIN) so that Vs is 630 mV.
Specification
TP5 (AMP IN)/MA-99 (C-3) Output waveform
.
Adjust so that Vs is 700 mV when AGC is ON
and 75
Z
terminator is on.
.
Adjust so that Vs is 630 mV when AGC is ON
and 75
Z
terminator is off.
Vs
Adjustments
AGC REF adjustment
1
RV3/MA-99 (C-2)
AGC GAIN adjustment
1
RV2/MA-99 (C-2)
1
RV3
1
RV2
TP5
MA-99
3-2.
Video Level Adjustment
Machine condition for adjustment
.
Input signal: 10 steps signal
.
In case, monitor is not connected, set DIP
switch
!=
on the rear panel to ON, if
connected, set to OFF.
.
Adjust RV4 (AGC OFF CONT) using 10
steps signal input.
Specification
TP5 (AMP IN)/MA-99 (C-3) Output waveform
Adjust so that video signal level is 1.0 V.
Adjustments
AGC OFF CONT
adjustment
1
RV4/MA-99 (C-2)
1.0 V
MA-99
TP5
1
RV4