Sony UP895 Service Manual - Page 24

Brightness and Contrast Adjustment, TP6 AD IN/MA-99 B-3 Output waveform

Page 24 highlights

3-3. Brightness and Contrast Adjustment Machine condition for adjustment Specification . Input signal: 10 steps signal . In case, monitor is not connected, set DIP switch != on the rear panel to ON, if connected, set to OFF. . Set CONTRAST and BRIGHT knobs to the center position on the front panel. TP6 (AD IN)/MA-99 (B-3) Output waveform TP7 (VRT)/MA-99 (B-3) Output voltage TP8 (VRB)/MA-99 (B-3) Output voltage 10 9 8 7 6 5 4 AD IN (TP6) 3 2 1 0 VRT (TP7) VRB (TP8) Adjustments C ADJ adjustment 1RV5/MA-99 (C-1) B ADJ adjustment 1RV6/MA-99 (C-1) MA-99 1RV5 1RV6 TP7 TP8 TP6 RV6 2 1 0 VRB Adjust RV6 so that mid voltage between 0 and 1 is equaled to the VRB voltage. RV5 10 9 8 VRT Adjust RV5 so that mid voltage between 9 and 10 is equaled to the VRT voltage. 3-2 UP-895/(E)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

3-2
UP-895/(E)
3-3.
Brightness and Contrast Adjustment
Machine condition for adjustment
.
Input signal: 10 steps signal
.
In case, monitor is not connected, set DIP
switch
!=
on the rear panel to ON, if
connected, set to OFF.
.
Set CONTRAST and BRIGHT knobs to
the center position on the front panel.
Specification
TP6 (AD IN)/MA-99 (B-3) Output waveform
TP7 (VRT)/MA-99 (B-3) Output voltage
TP8 (VRB)/MA-99 (B-3) Output voltage
Adjust RV6 so that mid voltage between 0 and
1 is equaled to the VRB voltage.
Adjust RV5 so that mid voltage between 9 and
10 is equaled to the VRT voltage.
Adjustments
C ADJ adjustment
1
RV5/MA-99 (C-1)
B ADJ adjustment
1
RV6/MA-99 (C-1)
MA-99
1
RV5
1
RV6
TP7
TP8
TP6
VRT
(TP7)
VRB
(TP8)
AD IN
(TP6)
0
1
2
3
4
5
6
7
8
9
10
RV6
VRB
0
1
2
RV5
VRT
8
9
10