Sony UP895 Service Manual - Page 46

Head Operation (Up & Down) is Out of Order, The head position sensors PH21 and PH22 on SE-531

Page 46 highlights

5-4. Head Operation (Up & Down) is Out of Order START Does head motor operate? YES Are signals from sensor available at pins 2 and 3 of CN2 on MA-99 board? YES IC400 and Q402 on MA-99 board are defective. NO The head position sensors (PH21 and PH22) on SE-531 NO board are defective. Pins 16 and 17 of IC304 on MA-99 board are defective. 5-4 UP-895/(E)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

5-4
UP-895/(E)
5-4.
Head Operation (Up & Down) is Out of Order
IC400 and Q402 on MA-99 board are defective.
NO
YES
Does head motor operate?
START
The head position sensors (PH21 and PH22) on SE-531
board are defective.
NO
YES
Are signals from sensor
available at pins 2 and 3 of CN2
on MA-99 board?
Pins 16 and 17 of IC304 on MA-99 board are defective.