TP-Link T2600G-18TSTL-SG3216 T2600G-18TSUN V1 Instalation Guide
TP-Link T2600G-18TSTL-SG3216 Manual
View all TP-Link T2600G-18TSTL-SG3216 manuals
Add to My Manuals
Save this manual to your list of manuals |
TP-Link T2600G-18TSTL-SG3216 manual content summary:
- TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 1
Business Networking Solution Installation Guide JetStream Gigabit L2 Managed Switch T2600G-18TS (TL-SG3216) T2600G-28TS (TL-SG3424) T2600G-52TS (TL-SG3452) T2600G-28MPS (TL-SG3424P) - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 2
- TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 3
of the switch. Chapter 5 Configuration This chapter instructs you to configure the switch via Web Interface and CLI commands. Appendix A Troubleshooting. Appendix B Hardware Specifications. Audience This Installation Guide is for: Network Engineer Network Administrator Conventions • The - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 4
17 4.4 Verify Installation 18 4.5 Power On 19 4.6 Initialization 19 Chapter 5 Configuration----------- 20 5.1 Configure the Switch via GUI 20 5.2 Configure the Switch Using CLI 21 Appendix A Troubleshooting--------- 24 Appendix B Hardware Specifications------ 26 II Contents - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 5
-52TS/T2600G28MPS from TP-Link provides wire-speed performance and full set of L2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 6
RJ45 port has a corresponding 1000Mbps LED and Link/Act LED. SFP Port Designed to install the SFP module. T2600G-28TS features 4 individual SFP ports and supports 1000M SFP module connection only. 02 Introduction - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 7
JetStream Gigabit L2 Managed Switch The front panel of The T2600G-52TS is shown as the following figure. Figure 1-3 Front Panel of T2600G-52TS Console(USB) Console Console Console (USB) (RJ45) LEDs 10/100/1000Mbps RJ45 Port SFP Port Console (USB) Port Designed to connect with the USB port of a - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 8
JetStream Gigabit L2 Managed Switch SFP Port Designed to install the SFP module. T2600G-52TS features 4 individual SFP ports and supports 1000M SFP module connection only. The front panel of The T2600G-28MPS is shown as the following figure. Figure 1-4 Front Panel of T2600G-28MPS LEDs - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 9
. Each 10/100/1000Mbps RJ45 port has a corresponding 1000Mbps LED. SFP Port Designed to install the SFP module. T2600G-28MPS features 4 individual SFP ports and supports 1000M SFP module connection only. Introduction 05 - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 10
JetStream Gigabit L2 Managed Switch Port Feature Model T2600G-18TS T2600G-28TS T2600G-52TS T2600G-28MPS 10/100/1000Mbps RJ45 Port 16 24 48 24 SFP Port 2 4 4 4 ■■ Rear Panel The rear panel of the switch is shown as the following figure. Figure 1-5 Rear Panel Console Port 2 2 2 2 Kensington - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 11
, please contact your distributor. One Switch One Power Cord, One Console Cable and One USB Cable This Installation Guide Business Networking Solution Installation Guide One Resouce CD Two mounting brackets and the fittings 2.2 Safety Precautions To avoid any device damage and bodily injury - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 12
, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table. Environment Operating Storage - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 13
the device on a rack or a flat workbench, please note the following items: ■■ The rack or workbench is flat and stable, and sturdy enough to support the weight of 5.5kg at least. ■■ The rack or workbench has a good ventilation system. The equipment room is well ventilated. ■■ The rack is well - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 14
Installation Feet Bottom of the Device Notch ■■ Rack Installation To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Check the grounding and stability of the rack. 2. Secure the supplied rack-mounting brackets to each side of the device with - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 15
JetStream Gigabit L2 Managed Switch Chapter 3 Lightning Protection 3.1 Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 16
small as possible. ■■ Requirements for the distance between Ethernet cable and other pipelines are shown in the table. Other Pipelines Down-conductor PE Service pipe Compressed air pipe Thermal pipe (not wrapped) Thermal pipe (wrapped) Gas pipe Ethernet Cable Min Parallel Net Length L (mm) 1000 50 - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 17
, which is also a necessary measure to protect the body from electric shock. In different environments, the device may be grounded differently. The following will instruct you to connect the device to the ground in two ways, connecting to the grounding bar or connecting to the ground via the power - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 18
JetStream Gigabit L2 Managed Switch Figure 3-2 Connecting to the Ground Switch (Rear Panel) AC Power Cord (with PE cable) Note: ■■ The figure is to illustrate the application and principle. The power plug you get from the package and the socket in your situation will comply with the regulation in - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 19
Figure 3-3 Equipotential Bonding JetStream Gigabit L2 Managed Switch Grounding Terminal Ground Cable Equipotential Bonding Cable Grounding Bar When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm2 at least. The shorter cable the better, - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 20
JetStream Gigabit L2 Managed Switch Figure 3-4 Equipotential Bonding Grounding Terminal Signal Lightning Arrester Equipotential Bonding Cable Device Ethernet Cable Note: Signal lightning arrester is not provided with our product. If needed, please self purchase it. 16 Lightning Protection - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 21
JetStream Gigabit L2 Managed Switch Chapter 4 Connection 4.1 Ethernet Port Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. Figure 4-1 Connecting the RJ45 Port RJ45 Port RJ45 Cable 4.2 SFP Port Figure 4-2 demonstrates the connection of SFP port - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 22
Console (USB) Port Console(USB) T2600G-28TS You can also manage the device through the console port, for details please refer to the CLI Reference Guide on the resource CD. Note: ■■ Console (RJ-45) port and Console (USB) port cannot be used cocurrently. Console (USB) port takes priority over the - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 23
JetStream Gigabit L2 Managed Switch ■■ The power socket, device and rack are well grounded. ■■ The device is correctly connected to other network devices. 4.5 Power On Plug in the negative connector of the provided power cord into the power socket of the device, and the positive connector into a - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 24
JetStream Gigabit L2 Managed Switch Chapter 5 Configuration 5.1 Configure the Switch via GUI 1. To access the GUI of the switch, open a web browser and type the default management address http://192.168.0.1 in the address field of the browser, then press the Enter key. Figure 5-1 Web Browser Note: - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 25
time on a Windows-based PC. The driver can be found on the attached CD and Download page of our official website. Refer to the User Guide to learn more about the installation. To log on to the switch by the console port on the switch, please take the following steps: 1. Connect - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 26
about configuring Telnet login mode and login authentication information should be configured through Console connection. For more details please refer to the CLI Reference Guide on the resource CD. Here we take login local mode as an example. 2. Make sure the switch and the PC are in the same - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 27
are admin), then press the Enter button so as to enter User EXEC Mode. Figure 5-7 Enter into the User EXEC Mode For detailed CLI configuration instructions, please refer to the CLI Reference Guide on the resource CD. Configuration 23 - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 28
JetStream Gigabit L2 Managed Switch Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? 1. Connect the console port of the PC the power again. 4. Make sure the IP address of your PC is set within the subnet of the switch. 24 Appendix A Troubleshooting - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 29
you have configured: configure Bits per second as 38400, Data bits as 8, Parity as None, Stop bits as 1, and Flow control as None. For more troubleshooting help, go to: http://www.tp-link.com/en/support/faq Appendix A Troubleshooting 25 - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 30
JetStream Gigabit L2 Managed Switch Appendix B Hardware Specifications Item Standards Transmission Medium LEDs Operating Temperature Storage Temperature Operating Humidity Storage Humidity Content IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3z, IEEE 802.3x, IEEE 802 - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 31
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in electric shock and voiding the limited warranty. If you need service, please contact us. • Avoid water and wet locations. - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 32
BSMI Notice 1 2 3 4 5 6 7 Industry Canada Statement CAN ICES-3 (A)/NMB-3(A) Explanation of the symbols on the product label Symbol Explanation AC voltage RECYCLING This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this - TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 33
- TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 34
- TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 35
- TP-Link T2600G-18TSTL-SG3216 | T2600G-18TSUN V1 Instalation Guide - Page 36
Website: http://www.tp-link.com Tel: +86 755 26504400 E-mail: [email protected] © 2016 TP-Link 7106506829 REV2.0.0