Thermador PRD486EDG Installation Instructions - Page 18
Wire Lead Connection, Wire Connection
![]() |
View all Thermador PRD486EDG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Step 6: Electrical Requirements, Connection & Grounding A 3- or 4-conductor supply may be connected to the terminal block. 3-WIRE LEAD CONNECTION 1. Remove upper nuts only from the terminal block studs. Do not remove nuts which secure range internal wiring leads. 2. Secure the neutral, grounded wire of the supply circuit, to the center stud of the terminal block with nut. (See Fig. 10). 3. Secure the L1 (black) and L2 (red) power leads to the outside terminal block studs (brass colored) with nuts. 4. Tighten nuts securely. 4-WIRE CONNECTION 1. Remove upper nuts only from the terminal block studs. Do not remove lower nuts which secure range internal wiring leads. 2. Remove ground strap screw and bend the strap up as shown in Fig. 11. 3. Secure the neutral wire to the center stud of the terminal block with nut. 4. Secure the L1 (black) and L2 (red) power leads to the outside terminal studs (brass colored) with nuts. 5. Secure the bare copper ground lead to the range chassis using the ground screw previously used for the ground strap. Be sure that neutral and ground terminals do not touch. 6. Tighten all connections securely. ® ® ® ® FIG. 9 Conductor Securement Upper Nut Cupped Washer Supply Wire Flat Washer FIG. 10 3 Wire Connection ® ® ® L1 Black FIG.11 Ground Strap L2 Red Neutral White Bend Ground Strap Up FIG. 12 Secure Neutral Wire ® ® ® L1 Black L2 Red Ground Wire 15