Thermador PRG486JDG Installation Manual - Page 8

Installation with Low Back or High Shelf, Installation with Included Flush Island Trim - 12

Page 8 highlights

Installation with Low Back or High Shelf 36" (914mm) Min. to combustible materials 313/8" (797mm) 29" (737mm) High Shelf 3" (76mm) 12" (306mm) Low Back Guard Combustible Materials 12" (305mm) 22" (559mm) 36 3/4" Max (933mm) 35 7/8" Min (911mm) 251/8" (638mm) minimum recess depth 281/2" (723mm) 483/4" (1238mm) Installation with Included Flush Island Trim 36" (914mm) min to combustible materials 12" (305mm) Min to Combustible material with Flush Island Trim Combustible Materials Note: For Flush Island Trim installations, counter surface should have a cantilever edge meeting the back section of the Flush Island Trim accessory. 36 3/4" Max (933mm) 35 7/8" Min (911mm)  As defined in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition). English 6 Flush Island Trim Cantilever Note: If an inner wall is used under the cantilever counter top, there should be a 1/8" (3mm) gap from the rear of the range to the inner wall. FIGURE 2: SIDE VIEW OF CLEARANCES

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

English 6
F
IGURE
2:
S
IDE
V
IEW OF
C
LEARANCES
Combustible Materials
48
3
/
4
” (1238mm)
28
1
/
2
” (
723mm
)
29
” (737mm)
31
3
/
8
” (797mm)
25
1
/
8
” (638mm)
High Shelf
12” (306mm)
to combustible
materials
36” (914mm) Min
.
22” (559mm)
3” (76mm)
36
3
/
4
” Max (933mm)
35
7
/
8
” Min (911mm)
Installation with Low Back or High Shelf
materials
36” (914mm) min
to combustible
Installation with Included Flush Island Trim
Cantilever
12” (305mm) Min
to Combustible
Flush Island
Trim
A
s defined in the
“National Fuel Gas
Code” (ANSI Z223.1,
Current Edition).
Low Back
Guard
12”
(305mm)
Note: For Flush Island
Trim installations,
counter surface should
have a cantilever edge
meeting the back section
of the Flush Island Trim
accessory.
Note: If an inner wall is
used under the cantilever
counter top, there should
be a 1/8” (3mm) gap from
the rear of the range to the
inner wall.
36
3
/
4
” Max (933mm)
35
7
/
8
” Min (911mm)
Flush Island Trim
Combustible Materials
material with
minimum
recess depth