Toshiba 70CT User Guide - Page 40
Battery pack, B5V,VCC output, B3V output, Power supply microcontroller, CPU environmental condition
View all Toshiba 70CT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
2 Troubleshooting Procedures 2.3 Power Supply Troubleshooting q Battery pack Error code Meaning 10h Battery voltage is over the limit 11h Battery charge current is over the limit 12h Battery discharge current is over the maximum allowed limit when there is no load 13h Battery voltage is under the limit q B5V,VCC output Error code Meaning 20h VCC voltage is over the limit 21h VCC voltage is under the limit 22h VCC does not start up when power supply is turned on q B3V output Error code Meaning 30h B3V voltage is over the limit 31h B3V voltage is under the limit 33h B3V does not start up when the power supply is turned on q Power supply microcontroller Error code Meaning 50h Firmware or program error q CPU environmental condition Error code Meaning 80h CPU temperature is outside the allowable range 88h CPU overheat (The CPU heat sensor has detected overheating and has automatically shut down) Libretto 50CT/70CT Maintenance Manual 2-7