ViewSonic IFP9850 IFP9850 User Guide - Page 101
Get-Function Listing, Get-Func°on Descrip°on, Get-Func°on Format, Send: Command Type=g
![]() |
View all ViewSonic IFP9850 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 101 highlights
Get-Function Listing The PC can interrogate the LFD for specific information. The Get-Function packet format consists of 9 bytes which is similar to the Set-Function packet structure. Note that the "Value" byte is always = 000. Get-Function Description: Length: Total Byte of Message excluding "CR". TV/DS ID Identification for each of TV/DS (01~98; default is 01). Command Type Identify command type, "g" (0x67h) : Get Command "r" (0x72h) : Valid command Reply "-" (0x2Dh) : Invalid command Reply Command: Function command code: One byte ASCII code. Value[1~3]: Three bytes ASCII that defines the value. CR 0x0D Get-Function Format Send: (Command Type="g") Name Length ID Command Type Command Value1 Value2 Value3 CR Byte 1 Byte 2 Count Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes 1 2~3 4 order 5 6 7 8 9 Reply: (Command Type="r" or "-") If the Command is valid, Command Type = "r" Name Length ID Byte 1 Byte 2 Count Byte Bytes 1 2~3 order Command Type 1 Byte 4 Command Value1 Value2 Value3 CR 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 5 6 7 8 9 If the Command is NOT valid, Command Type = "-" Name Byte Count Bytes order Length 1 Byte 1 ID 2 Byte 2~3 Command Type 1 Byte 4 CR 1 Byte 5 101