ViewSonic IFP9850 IFP9850 User Guide - Page 95

Protocol, Set-Function Listing

Page 95 highlights

Protocol Set-Function Listing The PC can control the Display for specific actions. The Set-Function command allows you to control the Display behavior at a remote site through the RS232 port. The Set-Function packet format consists of 9 bytes. Set-Function Description: Length: Total Byte of Message excluding "CR" LFD ID Identification for each of Display (01~98; default is 01) ID "99" means to apply the set command for all connected displays. Under such circumstances, only ID#1 display has to reply. The LFD ID can be set via the OSD menu for each Display. Command Type Identify command type, "s" (0x73h): Set Command "+" (0x2Bh): Valid command Reply "-" (0x2Dh): Invalid command Reply Command: Function command code: One byte ASCII code. Value[1~3]: Three bytes ASCII that defines the value. CR 0x0D Set-Function Format Send: (Command Type="s") Name Length ID Byte 1 Byte 2 Count Byte Bytes 1 2~3 order Command Type 1 Byte 4 Command Value1 Value2 Value3 CR 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 5 6 7 8 9 Reply: (Command Type="+" or "-") Name Byte Count Bytes order Length 1 Byte 1 ID 2 Byte 2~3 Command Type 1 Byte 4 CR 1 Byte 5 NOTE: When PC applies command to all displays (ID=99), only the #1 set needs to reply by the name of ID=1. 95

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

95
Protocol
Set-Func°on Lis°ng
The PC can control the Display for specific ac°ons. The Set-Func°on command
allows you to control the Display behavior at a remote site through the RS232 port.
The Set-Func°on packet format consists of 9 bytes.
Set-Func°on Descrip°on:
Length:
Total Byte of Message excluding “CR”
LFD ID
Identification for each of Display (01~98; default is 01)
ID “99” means to apply the set command for all connected
displays. Under such circumstances, only ID#1 display has to
reply.
The LFD ID can be set via the OSD menu for each Display.
Command Type
Identify command type,
“s” (0x73h): Set Command
“+” (0x2Bh): Valid command Reply
“-“ (0x2Dh): Invalid command Reply
Command:
Function command code: One byte ASCII code.
Value[1~3]:
Three bytes ASCII that defines the value.
CR
0x0D
Set-Func°on Format
Send: (Command Type=
s”)
Name Length
ID
Command Type
Command
Value1 Value2 Value3
CR
Byte
Count
1 Byte
2
Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1
Byte
Bytes
order
1
2~3
4
5
6
7
8
9
Reply: (Command Type=“+” or “-”)
Name
Length
ID
Command Type
CR
Byte
Count
1 Byte
2 Byte
1 Byte
1 Byte
Bytes
order
1
2~3
4
5
NOTE:
When PC applies command to all displays (ID=99), only the #1 set needs
to reply by the name of ID=1.