Viking VMOH330 Installation Instructions - Page 5
Ventilation System
View all Viking VMOH330 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
7 VENTILATION SYSTEM This Built-In Microwave Hood is designed for adaptation to three types of hood ventilation systems. Select the type required for your installation. A. RECIRCULATING Non-Vented, Ductless Operation The unit is shipped assembled for recirculating. NOTE: 1. The Exhaust Damper Assembly is not required for recirculating operation. 2. The Charcoal Filter should be replaced every 6 months, depending on use. 3. The Charcoal Filter is also sold as an accessory. See Use and Care Manual for ordering information. B. HORIZONTAL VENTILATION SYSTEM STEP 1 • Remove the screws (1) and (2) for opening the blower motor cover and save screws. Remove cover. See Figure 6. Blower motor cover • Lift blower unit out of mounting location. See Figure 8. Blower motor Figure 8 CAUTION: Do not pull or stretch blower wiring. STEP 3 • Turn the blower unit so that the fan blade openings are facing back (rear of unit). See Figure 9. CAUTION: Wires to blower unit must be routed properly to avoid pinching wires before reinstallation of cover plate. After : Fan blade openings facing Rear Figure 6 Back of OVEN STEP 2 • Remove the screws (3) for Blower attachment and save screws. See Figure 7. Before : Fan blade openings facing Front Figure 7 1.TINSKB278MRR0_Viking_VMOH330SS_OTR_Install_E,S,F.indd 5 E 5 Figure 9 1/31/19 11:07 AM