Xerox 750DP Fiery SI Color Server Administration Guide - Page 56

Calibrate

Page 56 highlights

22-32 Setting up the Fiery SI 6. Scroll the main setup menu to choose Calibration. Job Log Setup Calibration Change Password Clear Server Setup When you choose Calibration from the main setup menu, the following menu is displayed: Exit Calibration Calibrate Remove Calibration Calibration 7. Choose Calibrate, and perform calibration as described below. For more information, see the User Guide. 8. When you have finished, save changes. Calibrate Calibration options are summarized below. See the User Guide for calibration procedures and a fuller explanation of calibration options. At the server you can print a configuration page to find out when the printer was last calibrated. The start page also contains this information. (To print a configuration page from a Fiery SI in Idle status, press the Menu button to display the Functions screen, scroll down to select Print Pages, and select Configuration.) Canceling calibration. If any problems arise during calibration, press the Menu button to escape to the calibration menu. Calibration Method Densitometer/Copier glass Select Densitometer for measuring colors with an X-Rite DTP 32 densitometer connected to the Fiery SI serial port. Select Copier glass for AutoCal, which is quicker and doesn't require a densitometer.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114

2
2-32
Setting up the Fiery SI
6.
Scroll the main setup menu to choose Calibration.
When you choose Calibration from the main setup menu, the following menu is dis-
played:
7.
Choose Calibrate, and perform calibration as described below.
For more information, see the
User Guide.
8.
When you have finished, save changes.
Calibrate
Calibration options are summarized below. See the
User Guide
for calibration
procedures and a fuller explanation of calibration options. At the server you can print a
configuration page to find out when the printer was last calibrated. The start page also
contains this information. (To print a configuration page from a Fiery SI in Idle status,
press the Menu button to display the Functions screen, scroll down to select Print
Pages, and select Configuration.)
Canceling calibration.
If any problems arise during calibration, press the Menu but-
ton to escape to the calibration menu.
Calibration Method
Densitometer/Copier glass
Select
Densitometer
for measuring colors with an X-Rite DTP 32 densitometer con-
nected to the Fiery SI serial port. Select
Copier glass
for AutoCal, which is quicker and
doesn’t require a densitometer.
Job Log Setup
Calibration
Change Password
Clear Server
Setup
Exit Calibration
Calibrate
Remove Calibration
Calibration