Yamaha MU100R MU100R SOUND LIST - Page 10

Effect Parameter List - pdf

Page 10 highlights

Effect Parameter List Effect Parameter List Note • Parameters marked with a q in the "Control" column can be controlled from an AC1 (assignable controller 1) etc. However, this is valid only for a Variation effect (when selected for Insertion) and for Insertion effects 1/2. • Dry/Wet is valid only for a Variation effect (when selected for Insertion) and for Insertion effects 1/2. • Parameters 1 - 5 can be edited from the front panel of the MU100R. • Abbreviations used in the effect block diagrams LPF = Low Pass Filter HPF = High Pass Filter LSF = Low Shelving Filter HSF = High Shelving Filter PDF = Peak Dip Filter EF = Envelope Follower ER = Early Reflection q HALL1, 2 ROOM1, 2, 3 STAGE1, 2 PLATE (Reverb, Variation, Insertion1, 2 block) No. Parameter 1 Reverb Time 2 Diffusion 3 Initial Delay 4 HPF Cutoff 5 LPF Cutoff 6 7 8 9 10 Dry/Wet 11 Rev Delay 12 Density 13 Er/Rev Balance 14 High Damp 15 Feedback Level 16 Display 0.3 - 30.0s 0 - 10 0 - 63 Thru - 8.0kHz 1.0k - Thru D63>W - D=W - DR - E=R - EW - D=W - DR - E=R - E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

EFFECT
9
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Parameter
Reverb Time
Diffusion
Initial Delay
HPF Cutoff
LPF Cutoff
Dry/Wet
Rev Delay
Density
Er/Rev Balance
High Damp
Feedback Level
Display
0.3 – 30.0s
0 – 10
0 – 63
Thru – 8.0kHz
1.0k – Thru
D63>W – D=W – D<W63
0 – 63
0 – 4 (reverb, variation block)
0 – 2 (insertion1,2 block)
E63>R – E=R – E<R63
0.1 – 1.0
-63 – +63
See Table
table#4
table#5
table#3
table#3
table#5
Control
Value
0-69
0-10
0-63
0-52
34-60
1-127
0-63
0-4
0-2
1-127
1-10
1-127
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Parameter
Reverb Time
Diffusion
Initial Delay
HPF Cutoff
LPF Cutoff
Width
Heigt
Depth
Wall Vary
Dry/Wet
Rev Delay
Density
Er/Rev Balance
High Damp
Feedback Level
Display
0.3 – 30.0s
0 – 10
0 – 63
Thru – 8.0kHz
1.0k – Thru
0.5 – 10.2m
0.5 – 20.2m
0.5 – 30.2m
0 – 30
D63>W – D=W
– D<W63
0 – 63
0 – 4
E63>R – E=R – E<R63
0.1 – 1.0
-63 – +63
See Table
table#4
table#5
table#3
table#3
table#11
table#11
table#11
table#5
Control
Value
0-69
0-10
0-63
0-52
34-60
0-37
0-73
0-104
0-30
1-127
0-63
0-4
1-127
1-10
1-127
L
R
L
R
DELAY/ER
REV
DELAY/ER
HPF
LPF
HPF
LPF
+
+
+
L
R
L
R
REV
+
+
dry (L)
dry (R)
+
DELAY/ER
HPF
LPF
Effect Parameter List
Effect Parameter List
Note
Parameters marked with a
in the "Control" column can be controlled from an AC1 (assign-
able controller 1) etc. However, this is valid only for a Variation effect (when selected for Inser-
tion) and for Insertion effects 1/2.
Dry/Wet is valid only for a Variation effect (when selected for Insertion) and for Insertion effects
1/2.
Parameters 1 - 5 can be edited from the front panel of the MU100R.
Abbreviations used in the effect block diagrams
LPF = Low Pass Filter
HPF = High Pass Filter
LSF = Low Shelving Filter
HSF = High Shelving Filter
PDF = Peak Dip Filter
EF = Envelope Follower
ER = Early Reflection
HALL1, 2
ROOM1, 2, 3
STAGE1, 2
PLATE (Reverb, Variation, Insertion1, 2 block)
WHITE ROOM
TUNNEL
CANYON
BASEMENT (Reverb, Variation block)
Reverb Block
Variation, Insertion Block