Asko W6761 User manual General Use & Care Guide EN - Page 5

Electrical Connections, Drain Outlet Connection, Freestanding Installation, Stacked Installation, - instructions

Page 5 highlights

DRAIN OUTLET CONNECTION The machine is supplied with the outlet hose already attached. The hose should be extended over a suitable sink edge or drain pipe at a height of 24" to 36" (610 mm to 914 mm) above the bottom of the unit. (The lower height is preferable.) Make sure that the hose is not kinked. NOTE: If the hose is extended, the internal diameter of the coupling must not be less than 1/2". WARNING! Do not extend the drain hose higher than 36" (914 mm) from the bottom of the unit. ELECTRICAL CONNECTIONS The machine is delivered ready-fitted with a plug and is intended for connection to an ASKO Dryer, which is equipped with a matching receptacle. The plug supplied with the washer can only be used with an ASKO Dryer. If the washer is used separately or with another dryer, it must be on a separate 220 V single-phase circuit. If the machine is to be used in a wet area, the supply must be protected by a residual current device. As supplied: 230 V, 60 Hz 2000 W heating element 15 A fuse required WARNING! Connection to a permanently wired supply point must be made only by a qualified electrician. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING! Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. FREESTANDING INSTALLATION The washer can be placed next to the dryer. It is essential that the machine is leveled and the locknuts tight to prevent excessive vibration during the spin cycles. Also be sure to leave a minimum of 1/2" (12 mm) of space between the washer and the dryer. The height adjustment for the washer is 33-1/2" to 34-1/2" (850 mm to 876 mm). Do not raise it higher than 34-1/2". STACKED INSTALLATION ASKO washers should never be stacked on a counter or a dryer. You can, however, stack an ASKO dryer on an ASKO washer. Refer to your Dryer Use and Care Guide for instructions on how to do this. BUILT-IN INSTALLATION ASKO washers can be installed beneath a cabinet or worktop with a height of 34-1/2" ( 876 mm). There must be a gap of about 1/2" (12 mm) all around the machine, including between the rear edge of the machine top panel and the back wall. The opening width must be at least 24-1/2" (622 mm). Space must also be available for the inlet and drain hoses. See the diagram below for measurements and positions. If the drain outlet is higher than 24", the connections will need to be recessed. Page 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Page 5
ELECTRICAL CONNECTIONS
The machine is delivered ready-fitted with a plug and is
intended for connection to an ASKO Dryer, which is
equipped with a matching receptacle. The plug supplied
with the washer can only be used with an ASKO Dryer.
If the washer is used separately or with another dryer, it
must be on a separate 220 V single-phase circuit.
If the machine is to be used in a wet area, the supply
must be protected by a residual current device.
As supplied:
230 V, 60 Hz
2000 W heating element
15 A fuse required
DRAIN OUTLET CONNECTION
The machine is supplied with the outlet hose already
attached. The hose should be extended over a suitable
sink edge or drain pipe at a height of 24” to 36” (610
mm to 914 mm) above the bottom of the unit. (The lower
height is preferable.) Make sure that the hose is not
kinked.
NOTE:
If the hose is extended, the internal diameter
of the coupling must not be less than 1/2”.
WARNING!
Do not extend the drain hose higher than
36” (914 mm) from the bottom of the unit.
FREESTANDING INSTALLATION
The washer can be placed next to the dryer. It is essential
that the machine is leveled and the locknuts tight to
prevent excessive vibration during the spin cycles. Also
be
sure
to
leave
a
minimum
of
1/2”
(12 mm) of space between the washer and the dryer.
The height adjustment for the washer is 33-1/2” to
34-1/2” (850 mm to 876 mm). Do not raise it higher
than 34-1/2”.
STACKED INSTALLATION
ASKO washers should never be stacked on a counter
or a dryer. You can, however, stack an ASKO dryer on
an ASKO washer. Refer to your
Dryer Use and Care
Guide
for instructions on how to do this.
BUILT-IN INSTALLATION
ASKO washers can be installed beneath a cabinet or
worktop with a height of 34-1/2” ( 876 mm). There must
be a gap of about 1/2” (12 mm) all around the machine,
including between the rear edge of the machine top panel
and the back wall. The opening width must be at least
24-1/2” (622 mm).
Space must also be available for the inlet and drain
hoses. See the diagram below for measurements and
positions.
If the drain outlet is higher than 24”, the connections will
need to be recessed.
WARNING!
Connection to a permanently wired
supply point must be made only by a
qualified electrician.
GR
GR
GR
GR
GROUNDING INSTR
OUNDING INSTR
OUNDING INSTR
OUNDING INSTR
OUNDING INSTRUCTIONS
UCTIONS
UCTIONS
UCTIONS
UCTIONS
This appliance must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
for electric current. This appliance is equipped with a cord
having an equipment-grounding conductor and a
grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
WARNING!
Improper connection of the
equipment-grounding conductor can result in a
risk of electric shock. Check with a qualified
electrician or serviceman if you are in doubt as
to whether the appliance is properly grounded.
Do not modify the plug provided with the
appliance. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.