BenQ RM8602K RS232 & LAN Command List - Page 13

Get-function listing, Get-function description

Page 13 highlights

Get-function listing The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format consists of 5 bytes which are similar to the Set-Function packet structure. Note that the "Value" byte is always = 00. Get-function description Item Length TV ID Command Type Command Value [1~3] CR Description Total Bytes of messages excluding "CR" Identification for each of TV TV ID is "01" for LAN control & RS232 control Identify command type, "g" (0x67h): Get Command Function command code: One byte ASCII code Three bytes ASCII that defines the value NOTE: To get backlight senor, thermal sensor, and ambient sensor, you need four bytes ASCII that defines the value and the length is 9. 0x0D Get-function format Send: (Command Type="g") Name Length Byte count 1 Byte Bytes order 1 ID 2 Byte 2~3 Command type 1 Byte 4 Command 1 Byte 5 Value1 1 Byte 6 Value2 1 Byte 7 Value3 1 Byte 8 CR 1 Byte 9 Reply: (Command Type="r" or "-") If the Command is valid, Command Type ="r" Name Length ID Byte count 1 Byte 2 Byte Bytes order 1 2~3 Command type 1 Byte 4 Command 1 Byte 5 Value1 1 Byte 6 Value2 1 Byte 7 Value3 1 Byte 8 CR 1 Byte 9 If the Command is Not valid, Command Type="-" Name Length ID Command type Byte count 1 Byte 2 Byte 1 Byte Bytes order 1 2~3 4 CR 1 Byte 5 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

13
Get-function listing
The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format
consists of 5 bytes which are similar to the Set-Function packet structure. Note that the "Value" byte is
always = 00.
Get-function description
Item
Description
Length
Total Bytes of messages excluding "CR"
TV ID
Identification for each of TV
TV ID is “
01
” for LAN control
& RS232 control
Command Type
Identify command type,
"g" (0x67h): Get Command
Command
Function command code: One byte ASCII code
Value [1~3]
Three bytes ASCII that defines the value
NOTE: To get backlight senor, thermal sensor, and ambient sensor, you
need four bytes ASCII that defines the value and the length is 9.
CR
0x0D
Get-function format
Send: (Command Type="g")
Name
Length
ID
Command type
Command
Value1
Value2
Value3
CR
Byte count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
6
7
8
9
Reply: (Command Type="r" or "-")
If the Command is valid, Command Type ="r"
Name
Length
ID
Command type
Command
Value1
Value2
Value3
CR
Byte count
1 Byte
2 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5
6
7
8
9
If the Command is Not valid, Command Type="-"
Name
Length
ID
Command type
CR
Byte count
1 Byte
2 Byte
1 Byte
1 Byte
Bytes order
1
2~3
4
5