BenQ RM8602K RS232 & LAN Command List - Page 3
Introduction
View all BenQ RM8602K manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
Introduction This document describes the hardware interface spec and software protocols of RS232 interface communication between Commercial Display and PC or other control unit with RS232 protocol. This set protocol allows users to assign the ID in the command to control the specify ID monitor. The set protocol contains two sections command: Set-Function and Get-Function In this document, "PC" represents all the control units that can send or receive the RS232 protocol command. Wire arrangement Wire Arrangement P1 Color P2 1 Black 1 2 Brown 3 3 Red 2 4 Orange 4 5 Yellow 5 6 Green 6 7 Blue 7 8 Purple 8 9 Gray 9 Case Drain wire Case RS232 pin assignment Pin Description Pin Description 1 NC 2 RXD 3 TXD 4 NC 5 GND 6 NC 7 RTS 8 CTS 9 NC Use of crossover (null modem) cable requires use with PC. 3