Removing Magnetron

Page 19 highlights

D. REMOVING MAGNETRON (Figures 11 Through 13) (1) Remove the vent grille by loosening two screws. (Figure 11) (2) Remove the outcase. See page 7-6. (3) Remove three tap tite screws securing the magnetron to the wave guide. (4) Remove the magnetron VERY CAREFULLY. NOTES: • When removing the magnetron, make sure that its dome does not hit any adjacent parts, or it may be damaged. • When replacing the magnetron, be sure to install the magnetron gasket in the correct position and be sure that the gasket is in good condition. • After replacing the magnetron, check for microwave energy leakage with a survey meter Check microwave energy leakage must be below the limit of 5 mW/cm 2 . (All service adjustments should be made for minimum microwave energy leakage readings.) Figure 11 Door Vent Grille Mount,All (1 or 2 screws) Mounting Plate Out Case Controller Figure 12 (3 screws) Figure 13 7-8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

Vent Grille
Controller
(3 screws)
Door
Mounting
Plate
(1 or 2 screws)
Out Case
Mount,All
D.
REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove the vent grille by loosening two screws.
(Figure 11)
(2) Remove the outcase. See page 7-6.
(3) Remove three tap tite screws securing the
magnetron to the wave guide.
(4) Remove the magnetron VERY CAREFULLY.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
• After replacing the magnetron, check for microwave
energy leakage with a survey meter Check
microwave energy leakage must be below the limit of
5 mW/cm
2
. (All service adjustments should be made
for minimum microwave energy leakage readings.)
7-8
Figure 13
Figure 12