Bosch HMV9302 Service Manual - Page 34

Problem - E

Page 34 highlights

PROBLEM - E: Unit does not heat up even if display counts down when START key is touched for HIGH POWER cooking. 1 Check: 1. PRIMARY AND SECONDARY INTERLOCK SWITCHES 2. THERMOSTAT Check the contact of relay 2(see page 7-18) 2 NO continuity Contact OK Replace circuit board Normal circuit board Check contact of connector S1 Poor contact Contact OK Correct seating Replace circuit board Normal contact Normal circuit board Measure resistance of H.V.Transformer (see page 7-15) Resistance incorrect Replace H.V.T. Normal H.V.T. Resistance incorrect Replace H.V.C. Normal H.V.C. Normal resistance Check the continuity of H.V.C. (see page 7-16) Normal resistance Check the continuity of H.V.D. (see page 7-16) Abnormal Replace H.V.D. Normal H.V.D. Normal Replace Magnetron Normal Magnetron Runs Runs Runs Runs Runs Runs Runs 7-23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

7-23
PROBLEM - E:
Unit does not heat up even if display counts down when
START key is touched for HIGH
POWER cooking.
Check:
1.
PRIMARY AND SECONDARY INTERLOCK SWITCHES
2.
THERMOSTAT
1
2
Runs
Contact
OK
Resistance
incorrect
Check the continuity of
H.V.C. (see page 7-16)
Normal H.V.T.
Resistance
incorrect
Normal H.V.C.
Abnormal
Replace H.V.D.
Normal
Magnetron
Replace
Magnetron
Normal
Normal
H.V.D.
Check the
continuity of H.V.D.
(see page 7-16)
Replace H.V.C.
Normal
resistance
Replace H.V.T.
Normal
resistance
NO
continuity
Replace
circuit board
Normal
circuit board
Poor contact
Replace
circuit board
Normal
circuit board
Contact OK
Normal
contact
Correct
seating
Check contact of
connector S1
Check the contact of
relay 2(see page 7-18)
Measure resistance of
H.V.Transformer
(see page 7-15)
Runs
Runs
Runs
Runs
Runs
Runs