Bosch HMV9302 Service Manual - Page 27

Components, Test Procedures, Results, A, B, A, B

Page 27 highlights

COMPONENTS TEST PROCEDURES Measure the resistance: (1) Terminal to terminal Ohmmeter HIGH-VOLTAGE CAPACITOR Figure 25-a (2) Terminal to case Ohmmeter Figure 25-b Measure the continuity: (1) Forward Ohmmeter HIGH-VOLTAGE DIODE Figure 26-a (1) Reverse Ohmmeter Figure 26-b 7-16 RESULTS Normal reading: Momentarily indicates several ohms, and then gradually returns to infinite ohms. Abnormal reading: Indicates continuity or infinite ohms from the beginning. Normal readings: Infinite. Abnormal reading: Indicates continuity. Normal readings: continuity. Abnormal reading: Infinite. Normal readings: Infinite. Abnormal reading: continuity.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

7-16
COMPONENTS
TEST PROCEDURES
RESULTS
HIGH-VOLTAGE
CAPACITOR
HIGH-VOLTAGE
DIODE
Measure the resistance:
(1) Terminal to terminal
Ohm-
meter
Figure 25-a
(2) Terminal to case
Ohm-
meter
Figure 25-b
Measure the continuity:
(1) Forward
Ohm-
meter
Figure 26-a
(1) Reverse
Ohm-
meter
Figure 26-b
Normal reading:
Momentarily indicates several ohms,
and then gradually returns to infinite
ohms.
Abnormal reading:
Indicates continuity or infinite ohms
from the beginning.
Normal readings:
Infinite.
Abnormal reading:
Indicates continuity.
Normal readings:
continuity.
Abnormal reading:
Infinite.
Normal readings:
Infinite.
Abnormal reading:
continuity.