Bosch WTMC6321US User Guide - Page 5

Caution, Warning

Page 5 highlights

Please ask your dealer or inquire at your local authority about the current means of disposal. Before installing the dryer Unpacking the appliance d CAUTION d The dryer is very heavy. Do not lift it by yourself. Do not lift the appliance by projecting components (e.g. door) ć due to risk of breakage. CAUTION Remove the appliance packaging carefully to prevent damage to the surfaces. Check the dryer for transportation damage. Do not connect a dryer which is visibly damaged. If in doubt, contact your dealer. Supplied components For U.S.A. d CAUTION d The dryer is supplied without a power cord. The power cord must be connected by qualified persons only. CAUTION After removing the packaging, immediately remove any objects from the drum. The dryer is delivered as a complete unit. The operating instructions and supplied accessories can be found in the drum. Installation location d WARNING d Do not install the dryer: - outdoors - in an environment with dripping water, - near flammable materials, - in rooms which are at risk of frost, - in rooms which may contain gas or other fuels, - in cupboards with lockable doors or in alcoves. The installation room must be well ventilated, otherwise the dryer will operate below optimum performance. Do not operate the dryer at temperatures above 104°F (40°C) and below 41°F (5°C). Low temperatures affect the automatic program sequence and may prolong the drying times. The installation surface for the dryer must be clean, level and firm. Do not install the appliance on carpets! Compensate for uneven floors with the heightĆadjustable feet. Install the dryer and level side to side and front to back. Use a bubble level. Never remove the heightĆadjustable feet! The size of the installation area depends on the dimensions of the dryer. Ensure that there is adequate room for the swivel range of the door! Minimum Installation Clearances Closet Sides 0" (O mm) Top 12" (3O5 mm) Rear* 0" (O mm) * as close to wall as venting will allow. Important information concerning minimum distances: - Depending on the location of the exhaust air connection, an additional minimum distance of 5½ inch (14 cm) must be provided on this side for pipes/brackets (see page 7). - Distances above the indicated minimum dimensions reduce the risk of mold formation behind the appliance. - Additional distances reduce noise transmission. - Additional distances facilitate installation and service. - If the dryer is installed in a small room, the doors of the room must be fitted with vents of a specified minimum size. Dimension Weight a 27.0" (686 mm) 125 lbs b 31.8" (808 mm) (56 kg) with c 37.2" (945 mm) packaging d 19.7" (500 mm)/ 143 lbs angle 170Ć180° (64 kg) If installing the dryer in a closet, observe the minimum distances according to the following table: The dryer door is delivered with hinges on the right. If required, the door hinges can be switched to the left side. If the door hinges are to be changed over, please contact your dealer or our customer serviceĆteam (see page 22). 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

5
Please ask your dealer or
inquire at
your
local
authority
about the current
means
of
disposal.
Before
installing
the±dryer
Unpacking the
appliance
d
CAUTION
d
The dryer
is
very
heavy.
Do
not
lift it by yourself.
Do
not
lift
the
appliance by
projecting
components (e.g. door) ć
due to
risk
of
breakage.
CAUTION
Remove
the appliance
packaging carefully
to
prevent
damage
to the surfaces.
Check the dryer for transportation
damage.
Do not
connect
a dryer
which
is
visibly damaged.
If
in doubt,
contact
your
dealer.
Supplied components
For
U.S.A.
d
CAUTION
d
The dryer
is
supplied
without
a±power
cord.
The power cord
must
be
connected by qualified
persons
only.
CAUTION
After removing
the packaging,
immediately
remove
any objects
from the
drum.
The dryer
is
delivered
as a complete
unit. The
operating
instructions
and
supplied
accessories
can
be found in
the drum.
Installation location
d
WARNING
d
Do not
install
the
dryer:
-
outdoors
-
in an
environment
with
dripping
water,
-
near
flammable
materials,
-
in
rooms
which
are at
risk
of
frost,
-
in
rooms
which
may contain
gas
or other fuels,
-
in
cupboards
with
lockable
doors
or in
alcoves.
The installation
room must be well
ventilated,
otherwise
the dryer will
operate
below optimum
performance.
Do
not operate
the dryer at
temperatures
above 104
°
F
(40
°
C) and
below
41
°
F
(5
°
C).
Low temperatures
affect the automatic
program
sequence
and may
prolong
the drying
times.
The installation
surface
for
the dryer
must be clean,
level
and
firm. Do
not
install
the
appliance
on
carpets!
Compensate
for
uneven
floors
with
the
heightĆadjustable
feet.
Install
the dryer and
level
side to
side
and front to
back.
Use a bubble level.
Never
remove the heightĆadjustable
feet!
The size of
the installation
area
depends
on
the dimensions
of
the
dryer.
Ensure that there is
adequate
room for the swivel
range of
the door!
Dimension
Weight
a
27.0" (686 mm)
125 lbs
(56 k )
b
31.8" (808 mm)
(56 kg)
with
c
37.2" (945 mm)
with
packaging
d
angle
19.7" (500 mm)/
170Ć180°
packaging
143 lbs
(64 kg)
If
installing
the dryer in
a closet,
observe
the minimum
distances
according
to
the following
table:
Minimum
Installation
Clearances
Closet
Sides
0" (O mm)
Top
12" (3O5 mm)
Rear*
0" (O mm)
*
as
close
to wall
as
venting
will
allow.
Important
information
concerning
minimum
distances:
-
Depending
on
the location
of the
exhaust
air
connection,
an
additional
minimum
distance
of
inch
(14
cm) must be provided
on
this
side for
pipes/brackets
(see
page 7).
-
Distances
above the indicated
minimum
dimensions
reduce the
risk
of
mold formation
behind the
appliance.
-
Additional
distances
reduce noise
transmission.
-
Additional
distances
facilitate
installation
and
service.
-
If
the dryer is
installed
in
a small
room, the doors of
the room
must
be fitted with
vents
of a specified
minimum
size.
The dryer
door is
delivered
with hinges
on
the right. If
required,
the door hinges
can
be switched
to
the left side.
If
the door hinges
are to be changed
over,
please contact your
dealer or our
customer
serviceĆteam
(see±page±22).