Brother International BAS-612 Instruction Manual - English - Page 50

Circuit, Board, Switches

Page 50 highlights

MAIN CIRCUIT BOARD DIP SWITCHES Be sure to set the power switch to OFF before changing the dip switch settings. SW1 ON sw11 12 13 14 15 16 17 18 OFF Lock-stitch stitch length PSW-11 OFF ON OFF ON OFF ON OFF ON PSW-12 OFF OFF ON ON OFF OFF ON ON PSW-13 OFF OFF OFF OFF ON ON ON ON (mm) 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 * When the BAS-612 is used, the V back-stitching will start even if the PSW-14 is set. Fraying prevention PSW-14 ON: (Backstitch) OFF: (Condensed) SW 2 SW4 SW1 SW3 SW2 ON sw21 22 23 24 25 26 27 28 Li OFF Backstitch stitch length Condensed stitch length Backstitch stitch length Condensed stitch length PSW-15 OFF ON OFF ON .PSW-.16 OFF OFF ON ON (mm) 0.8 1.2 1.6 2.0 PSW-17 OFF ON OFF ON PSW-18 OFF OFF ON ON (rnm) 0.4 0.6 0.8 1.0 PSW-21 OFF ON OFF ON SW-22 OFF OFF ON ON I (mm) 3.0 4.0 5.0 6.0 Machine speed PSW-23 ON: (2.500 spm) OFF: 2,200 spm Carriage feed speed to corner knife position ON: 20 m/min. PSW-24 OFF: 15 m/min. PSW-25 OFF ON OFF ON PSW-26 OFF OFF ON ON Carriage feed operating / Right Left Simultane- Simultane- it , left , right ous R & L ous carriage sequence carriage feed and flap / feed presser Flap sensor operating sequence Right flap : Right -.left ON PSW P7 Left flap : Left -.right Right flap : Left , Right OFF Left flap : Right , left Switch operation PSW-28 ON: Foot OFF: Timer start -46-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

MAIN
CIRCUIT
BOARD
DIP
SWITCHES
Be
sure
to
set
the
power
switch
to
OFF
before
changing
the
dip
switch
settings.
SW1
ON
sw11
12
13
14
15 16
17
18
OFF
SW
2
SW4
SW1
SW3
SW2
ON
sw21
22
23
24
25 26
27
28
Li
OFF
Lock
-stitch
stitch
length
PSW-11
OFF
ON
OFF
ON
OFF
ON
OFF
ON
PSW-12
OFF
OFF
ON
ON
OFF
OFF
ON
ON
PSW-13
OFF OFF OFF OFF
ON
ON
ON
ON
(mm)
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
*
When
the
BAS
-612
is
used,
the
V
back
-stitching
will
start
even
if
the
PSW-14
is
set.
Fraying
prevention
PSW-14
ON:
(Backstitch)
OFF:
(Condensed)
Backstitch
stitch
length
PSW-15
OFF
ON
OFF
ON
.
PSW-.16
OFF OFF
ON
ON
(mm)
0.8
1.2
1.6
2.0
Condensed
stitch
length
PSW-17
OFF
ON
OFF
ON
PSW-18
OFF OFF
ON
ON
(rnm)
0.4
0.6
0.8
1.0
Backstitch
stitch
length
Condensed
stitch
length
PSW-21
OFF
ON
OFF
ON
SW
-22
OFF OFF
ON
ON
I
(mm)
3.0
4.0
5.0
6.0
Machine
speed
PSW-23
ON:
(2.500
spm)
OFF:
2,200
spm
Carriage
feed
speed
to
corner
knife
position
PSW-24
ON:
20
m/min.
OFF:
15
m/min.
Carriage
feed
operating
sequence
PSW-25
OFF
ON
OFF
ON
PSW-26
OFF
OFF
ON
ON
/
/
Right
,
left
Left
,
right
Simultane-
ous
R
&
L
carriage
feed
Simultane-
ous
carriage
feed
and
flap
presser
Flap
sensor
operating
sequence
PSW
P7
ON
Right
fl
ap
:
Right
—.left
Left
fl
ap
:
Left
—.right
OFF
Right
fl
ap
:
Left
,
Right
Left
fl
ap
:
Right
,
left
Switch
operation
PSW-28
ON:
Foot
OFF:
Timer
start
it